51
STEP 4
Turn on membrane system by turning LP feed air
valve switch to ON position (Fig. 65).
Feed air will now pass through the LP regulator
“B” and LP filtration “C” and continue on to the
membrane heater (Fig. 66).
LP regulator and thermostat have been factory
set and may only need fine-tuning.
Allow system to stabilize and come up to
pressure and temperature, (approximately 5-8
minutes).
Regulator pressure “D” range will be
approximately 10-12 Bar.
Temperature “E” range will be between 35 °C
and 43 °C (95° – 110° F) (Fig. 67).
65
66
67