6.3 HIGH GAS PRESSURE TEST
The instructions below apply to both the Natural Gas and Propane gas trains.
To simulate a high gas pressure fault, refer to Figure 6-1B and perform the following steps:
High Gas Pressure Test
1. Remove the 1/4“ plug from the leak detection ball valve at the High Gas Pressure switch,
shown in Figure 6-1B.
2. Install a 0 – 16” W.C. manometer (or W.C. gauge) where the 1/4” plug was removed.
3. Slowly open the leak detection ball valve near the High Gas Pressure switch.
4. Start the unit in Manual mode at a valve position (firing rate) between
25
and
30
%.
5. With the unit running, monitor the gas pressure on the manometer installed in step 2 and
record the gas pressure reading.
6. Slowly increase the gas pressure using the adjustment screw on the SSOV (see Figure
4-3 in Chapter 4).
7. The unit should shut down and display a
GAS PRESSURE
fault message, and the
FAULT indicator should also start flashing at the following approximate pressures:
•
BMK 750 & 1000
– NATURAL GAS gas trains:
4.7” W.C.
•
BMK 750
– PROPANE gas train:
4.7” W.C.
•
BMK 1000
– PROPANE gas train:
10.5” W.C.
8. Reduce the gas pressure back to the value recorded in step 5. This pressure should be
within the range of
•
BMK 750 & 1000 –
NATURAL GAS gas trains:
2.0” W.C. ± 0.4” W.C.
•
BMK 750 –
PROPANE gas train:
3.9” W.C. ± 0.2” W.C.
•
BMK 1000 – PROPANE gas train: 7.4” W.C. ± 0.2” W.C.
9. Press the
CLEAR
button on the Control Box to clear the fault.
10. The fault message should clear and the
FAULT
indicator should go off. The unit should
restart.
11. Upon test completion, close the ball valve and remove the manometer. Replace the
1/4“plug removed in step 1.