35 Chapter3
change the radious server port
8021x system accountport
[port ID]
G
Use the 802.1x system account
port global configuration command
to change the accounting port
switch(config)#
8021x system accountport 1816
8021x system sharekey
[ID]
G
Use the 802.1x system share key
global configuration command to
change the shared key value.
switch(config)#
8021x system sharekey 123456
8021x system nasid
[words]
G
Use the 802.1x system nasid
global configuration command to
change the NAS ID
switch(config)#
8021x system nasid test1
8021x misc quietperiod
[sec.]
G
Use the 802.1x misc quiet period
global configuration command to
specify the quiet period value of
the switch.
switch(config)#
8021x misc quietperiod 10
8021x misc txperiod
[sec.]
G
Use the 802.1x misc TX period
global configuration command to
set the TX period.
switch(config)#
8021x misc txperiod 5
8021x misc supportimeout
[sec.]
G
Use the 802.1x misc supp timeout
global configuration command to
set the supplicant timeout.
switch(config)#
8021x misc supportimeout 20
8021x misc servertimeout
[sec.]
G
Use the 802.1x misc server
timeout global configuration
command to set the server
timeout.
switch(config)#
8021x misc servertimeout 20
8021x misc maxrequest
[number]
G
Use the 802.1x misc max request
global configuration command to
set the MAX requests.
switch(config)#
8021x misc maxrequest 3
8021x misc reauthperiod
[sec.]
G
Use the 802.1x misc reauth period
global configuration command to
set the reauth period.
switch(config)#
8021x misc reauthperiod 3000
8021x portstate
[disable | reject | accept | authorize]
I
Use the 802.1x port state interface
configuration command to set the
state of the selected port.
switch(config)#
interface fastethernet 3
switch(config-if)#
8021x portstate accept
show 8021x
E
Displays a summary of the 802.1x
properties and also the port sates.
switch>
show 8021x
no 8021x
G
Disable 802.1x function
switch(config)#
no 8021x
3.1.14
TFTP Commands Set
Table 3.14: TFTP Commands Set
Netstar Commands
Level
Description
Defaults Example
backup flash:backup_cfg
G
Save configuration to TFTP and need
to specify the IP of TFTP server and
the file name of image.
switch(config)#
backup flash:backup_cfg
restore flash:restore_cfg
G
Get configuration from TFTP server
and need to specify the IP of TFTP
server and the file name of image.
switch(config)#
restore flash:restore_cfg
upgrade flash:upgrade_fw
G
Upgrade firmware by TFTP and need
to specify the IP of TFTP server and
the file name of image.
switch(config)#
upgrade lash:upgrade_fw
3.1.15
SystemLog, SMTP and Event
Table 3.15: SysLog,SMTP,Event Commands Set
Netstar Commands
Level
Description
Example
systemlog ip
[IP address]
G
Set System log server IP address.
switch(config)#
systemlog ip 192.168.1.100
Содержание EKI-7659C
Страница 1: ...EKI 7659C Industrial 8 2G Combo Ports Managed Redundant Gigabit Ethernet Switch User Manual ...
Страница 12: ...EKI 7659C User Manual xii C 7 System Reboot 135 Figure C 68 System Reboot 135 ...
Страница 20: ...EKI 7659C User Manual 8 ...
Страница 23: ...11 Chapter2 2 2 Dimensions units mm Figure 2 1 Front View of EKI 7659C ...
Страница 24: ...EKI 7659C User Manual 12 Figure 2 2 Side View of EKI 7659C ...
Страница 25: ...13 Chapter2 Figure 2 3 Rear View of EKI 7659C ...
Страница 26: ...EKI 7659C User Manual 14 Figure 2 4 Top View of EKI 7659C ...
Страница 34: ...EKI 7659C User Manual 22 ...
Страница 35: ...23 Chapter3 Configuration Sections include z RS 232 Console z Web Browser z Mounting z Self Diagnosis CHAPTER ...
Страница 65: ...53 Chapter3 Figure 3 21 User Authentication ...
Страница 71: ...59 Chapter3 Figure 3 28 Rate Limiting ...
Страница 94: ...EKI 7659C User Manual 82 ...
Страница 95: ...83 Troubleshooting CHAPTER ...
Страница 97: ...85 Pin Assignment Wiring APPENDIX ...
Страница 100: ...EKI 7659C User Manual 88 ...
Страница 101: ...89 Compatible SFP Modules APPENDIX ...
Страница 103: ...91 APPENDIX X View ...
Страница 141: ...129 when the X Ring function enable And then click Apply to apply the configuration Figure C 61 X Ring ...