EKI-7659C User Manual
112
C.2.4 Port Trunk
The Link Aggregation Control Protocol (LACP) provides a standardized means for
exchanging information between Partner Systems on a link to allow their Link
Aggregation Control instances to reach agreement on the identity of the Link
Aggregation Group to which the link belongs, move the link to that Link Aggregation
Group, and enable its transmission and reception functions in an orderly manner. Link
aggregation lets you group up to 4 consecutive ports into two dedicated connections.
This feature can expand bandwidth to a device on the network. LACP operation
requires full-duplex mode, more detail information refers to IEEE 802.3ad.
•
Trunk No.:
There are four trunk groups to provide configuration.
•
Type:
Pull down the selection menu item to select the type as ‘Static’ or ‘802.3ad
LACP’.
•
Member ports:
allows max four ports to be aggregated at the same time. With
LACP dynamic trunk group, the exceed ports are standby and can be aggregated if
work ports fail. If it is static trunk group, the number of ports must be the same as the
group member ports.
•
Click ’Apply’ button to carry the setting into effect
.
Figure C.35: Port Trunk
Port Trunk Status:
This function displays the Group ID, Trunk Member and Type.
Содержание EKI-7659C
Страница 1: ...EKI 7659C Industrial 8 2G Combo Ports Managed Redundant Gigabit Ethernet Switch User Manual ...
Страница 12: ...EKI 7659C User Manual xii C 7 System Reboot 135 Figure C 68 System Reboot 135 ...
Страница 20: ...EKI 7659C User Manual 8 ...
Страница 23: ...11 Chapter2 2 2 Dimensions units mm Figure 2 1 Front View of EKI 7659C ...
Страница 24: ...EKI 7659C User Manual 12 Figure 2 2 Side View of EKI 7659C ...
Страница 25: ...13 Chapter2 Figure 2 3 Rear View of EKI 7659C ...
Страница 26: ...EKI 7659C User Manual 14 Figure 2 4 Top View of EKI 7659C ...
Страница 34: ...EKI 7659C User Manual 22 ...
Страница 35: ...23 Chapter3 Configuration Sections include z RS 232 Console z Web Browser z Mounting z Self Diagnosis CHAPTER ...
Страница 65: ...53 Chapter3 Figure 3 21 User Authentication ...
Страница 71: ...59 Chapter3 Figure 3 28 Rate Limiting ...
Страница 94: ...EKI 7659C User Manual 82 ...
Страница 95: ...83 Troubleshooting CHAPTER ...
Страница 97: ...85 Pin Assignment Wiring APPENDIX ...
Страница 100: ...EKI 7659C User Manual 88 ...
Страница 101: ...89 Compatible SFP Modules APPENDIX ...
Страница 103: ...91 APPENDIX X View ...
Страница 141: ...129 when the X Ring function enable And then click Apply to apply the configuration Figure C 61 X Ring ...