Electrical installation
Advantech-DLoG
DLT-V4108 Manual, V01 Prelim
59 / 81
15.2.
Connecting DLT-V4108 to the power supply
DLT-V4108 is available with a galvanically separated, integrated DC power supply. Power is
connected to the back of the device using a Phoenix contact connector. There is no power switch
for the mains voltage.
WARNING
Hazardous voltage, electric shock on the DLT-V4108 with DC power supply unit.
−
Do not put the DLT-V4108 into operation if it is damaged.
−
Do not open or modify the DLT-V4108.
−
Only connect or disconnect electrical connections when the device is in a de-energized
state (electrically dead).
−
Use only original power supply cables from Advantech-DLoG. Advantech-DLoG power
cables meet the specific requirements for low-temperature flexibility, UV resistance, oil
resistance, etc.
If other power supply cables are used: The user/operator of the DLT-V4108 is solely
responsible for the resulting damage.
−
Make sure that the power supply cables are run without kinks and are mechanically
protected (securely protected against crushing and abrading).
−
The DC+ connecting cable must be protected by a fuse (30 AT max.).
−
The ignition connecting cable must be protected by a fuse of the following type:
5x20 mm T 125 mA L / 250 V, for example, a Wickmann 195-125 mA / 250 V.
−
Observe correct voltage ranges.
−
Ensure that power supply cable is fused correctly.
−
Observe the labeling on the cable and connect the power supply cable with the correct
polarity.
−
Cut the supply cable to the minimum length. This avoids tangled cables and improves the
quality of the power supply.
−
Connect the power supply cable to a suitable place. Ensure that the connecting cable has
an adequate cross section and ampacity at the connection point.
−
DLT-V4108 industrial PCs may only be connected to a SELV circuit (Safety Extra Low
Voltage).