Electrical installation
60 / 81
DLT-V4108 Manual, V01 Prelim
Advantech-DLoG
15.2.1.
Electrical connection of the DLT-V4108 to vehicles
DANGER
Danger to life due to electric shock.
−
Ground the DLT-V4108 in accordance with the vehicle manufacturer's instructions.
−
Observe the vehicle manufacturer’s instructions for connecting additional loads, for
example, in conjunction with an emergency shut-off switch.
−
Be sure that the connection of the power supply cables is as direct as possible to the
battery and not to power supply cables with a great deal of interference (e.g. the motor
power supply) or otherwise affected by consumers.
Electrical shock due to insufficient EMERGENCY shut-off of the vehicle.
If the EMERGENCY-OFF switch of the vehicle does not switch off the DLT-V4108, there is a
risk of electrical shock.
−
Install the DLT-V4108 and the EMERGENCY-OFF switch so that the DLT-V4108 also
switches off when the EMERGENCY-OFF switch is operated.
Observe
: If a DLT-V4108 with integrated UPS is installed in a vehicle, the EMERGENCY-OFF
switch of the vehicle has no effect on the DLT-V4108. This also applies to the peripherals
supplied by the device.