Electrical installation
58 / 81
DLT-V4108 Manual, V01 Prelim
Advantech-DLoG
15.
Electrical installation
15.1. Safety notice – observe before connecting
WARNING
Risk of injury and damage due to improper electrical connection.
Only authorized skilled personnel are permitted to perform the electrical connection of the
DLT-V4108. If the electrical connection of the DLT-V4108 is performed improperly, any DLoG
GmbH warranty for this device will be void.
−
Comply with the appropriate national installation regulations for the cable routing.
−
Do not connect/disconnect any cables during thunderstorms.
Power supply unit fuse blows repeatedly
If the fuse of the integrated power supply units blows again immediately after replacement,
there is a risk of electrical shock:
−
Send in the DLT-V4108 immediately for repair.
Electrical shock due to lack of disconnecting device.
DLT-V4108 industrial PCs are not equipped with disconnecting devices that are accessible
from the outside; they do not have switches. To enable the devices to be quickly disconnected
from the power supply in emergency situations:
−
Install an easily accessible disconnecting device close to the device.
−
Make sure that the disconnecting device disconnects all power supply lines.
Please note
: Because of the integrated UPS the DLT-V4108 device may be in operation
despite the disconnecting device being actuated, since it is supplied with power by the UPS.