Specifications A-3
LED Indicators
SENSE LED: Colors indicate Sensor firing, CPU
serial communications, data logging, and
firmware upgrade activities.
COMMS LED: Colors indicate modem
communication, power, and registration.
Calculating the Total Days of Storage Available
This section includes a special equation to use in determining the number of days of data that can be stored
in the
ECHO
monitor memory based on a specific application. Consider the following when calculating
the total days:
•
The monitor memory holds 3,784,704 bytes of data.
•
The log rate determines the number of readings taken per day. At a
5-minute
sample rate, the monitor
will record 288 readings a day for a single entity. At a
1-minute
sample rate, the monitor will record
1,440 readings a day for a single entity.
•
One entity reading consumes 6 bytes of monitor memory.
•
The date/time stamp for a reading is also equal to one reading.
•
Deduct 2 to 3 days from the total days of storage to compensate for additional overhead in memory.
Following is the equation for calculating the total days of storage available in the monitor memory:
Data Storage Available in the Monitor (in Bytes)
=
Total Days of
Storage in the
Monitor
Memory
Number of
Readings
Taken per
Day for
One entity
X
Memory
Consumed for
One Entity
Reading
(Date/Time
Stamp)
X
Number of
Entities Logged
by the Monitor
For example, recording
LRDEPTH
,
UNIDEPTH
, and
INTTEMP
offers approximately 545 days of data
storage.
3,784,704 bytes
=
548 days (
545 days
when accounting for
overhead
)
288 readings
X
6 bytes
X 4 entities (including
1 for the date/ time
stamp)
Sensor Specifications
The following table contains the specifications for measuring sensors within the
ECHO
monitor.
The Long Range Depth sensor is a long range ultrasonic sensor that measures the depth of flow at long
range.
Long Range Depth (Ultrasonic) Depth Sensor
Deadband
0.00 inches (0 mm)
Range
0.00 inches from the bottom of the parabolic
reflector to 240 inches (6.1 m)
Frequency
75 kHz
Resolution
0.01 inches (0.25 mm)
Содержание ECHO 9000
Страница 13: ...Introduction and Overview 1 9 First Page of the ECHO IECEx Certificate of Conformity ...
Страница 16: ...1 12 ADS ECHO Manual Sample ECHO Declaration of Conformity Page 1 ...
Страница 17: ...Introduction and Overview 1 13 Sample ECHO Declaration of Conformity Page 2 ...
Страница 61: ...Hardware Installation 3 21 Manhole Depth and Physical Offset Measurements ...