ADPRO
iFT Series Hardware Installation Manual
27817_08
35
Normally open – NEOL
Short circuit = alarm
Open circuit = idle
(Default setting)
Normally open – SEOL
Short circuit = alarm
1K1 = idle
Open circuit = tamper
Normally closed – NEOL
Short circuit = idle
Open circuit = alarm
Normally closed – SEOL
Short circuit = tamper
1K1 = idle
Open circuit = alarm
Normally open – DEOL
Short circuit = tamper
1K1 = alarm
3K3 = idle
Open circuit = tamper
Normally closed – DEOL
Short circuit = tamper
1K1 = idle
3K3 = alarm
Open circuit = tamper
7.2.3
Connecting Inputs and Outputs
Depending on the type, the I/O card can be equipped with Dinkle (standard) or Phoenix spring insertion
connectors. For both types you need a 2 mm slotted screwdriver.
Warning!
Although the picture below shows only the connector, it is strongly recommended to connect the
wires with the connectors plugged into the card. Wiring a handheld connector may cause injuries.
Wiring to Dinkle and Phoenix connectors is identical, except that the position of tabs and holes is swapped. The
picture in the procedure below shows a Phoenix connector.
To connect inputs and outputs, proceed as follows:
1.
Push the slotted tab firmly inwards with the screwdriver.
2.
Insert the stripped wire (6–7 mm) into the corresponding round hole as deeply as possible.
3.
Release the tab and pull the wire to check if it is properly fitted.
Wire gauge:
Solid and stranded: 16–24 AWG
(diam. 1.3–0.5 mm)