XO I/O Interface USB Modules
8.1
About the XO I/O Interface USB Modules
Firmware version XO 4.0 and above supports the XO I/O Interface USB modules for extra inputs and outputs.
These modules contain sets of Main I/O and Extension I/O cards (Next Generation) that you can connect to your
XO device via USB.
XO I/O Interface USB module:
Rear view, single module:
The XO I/O Interface USB modules function just like internal MIO/EIO Next Generation cards, but with the
following restrictions:
l
There are no AUDIO OUT and AUDIO GND outputs: if you want to use a VM22A audio switcher, you have to
connect it to the built-in MIO card instead. It is possible to use a VM22E switcher.
l
You can add only one set of MIO/EIO cards to your device = a single XO I/O Interface USB module. You then
have two MIO cards and one EIO card in total. You cannot use the double module.
You have to map the modules to the correct card set (MIO-1 or MIO-2) using the
hardware configuration tool
. If
not, the XO device will not discover the cards and you will not be able to use the inputs/outputs.
Furthermore, if you are using adapters on the USB ports of your XO device (to connect to PIR detectors or for
PTZ control of analogue cameras), you also have to map these 'devices' using the hardware configuration tool. If
the system detects a mismatch between the items configured in the hardware configuration tool and the hardware
that the system has detected (either more or less than configured), the system will activate system input 0002 –
[SYST] – HW CFG MISMATCH.
For detailed information, see the
XO I/O Interface USB Module Technical Manual
(32688).
Note
Although it is technically possible to disable an existing, built-in MIO/EIO card in the hardware
configuration tool, and use an external module instead, Honeywell recommends to keep and use the
built-in cards. If you disable a built-in MIO card, you have to switch off the buzzer and watchdog
features, or the system will beep continuously. Switching off the buzzer and watchdog seriously
reduces the system's reliability and security.
Caution!
Using the XO I/O Interface USB modules changes the internal USB port numbering on the XO device.
The default numbering as indicated in the hardware manuals no longer applies. If you have any other
devices than XO I/O Interface USB modules on the USB ports of your XO device, you also must
remap these devices in the hardware configuration tool, and you must adjust the serial port settings in
the XO client.
When you stop using XO I/O Interface USB modules on the XO device, you have to reset the
USB port numbering in the hardware configuration tool to return to the default USB port numbers.