170
Function Library
AxisNo
: Axis number
Counter
: Specified Counter
Counter = 0 , Command counter
Counter = 1 , Feedback counter
Counter = 2 , Error Counter
Counter = 3 , General Counter
Pos
: Latched counter value,
PLimit
: Soft limit value in positive direction
NLimit
: Soft limit value in negative direction
Action
: The reacting method of soft limit
Action =0, INT only
Action =1, Immediately stop
Action =2, slow down then stop
Action =3, reserved
Tolerance
: The tolerance of step-losing detection
On_Off
: Enable / Disable step-losing detection
On_Off =0, Disable
On_Off =1, Enable
CmpSrc
: The comparing source counter
CmpSrc =0, Command Counter
CmpSrc =1, Feedback Counter
CmpSrc =2, Error Counter
CmpSrc =3, General Counter
CmpMethod
: The comparing method
CmpMethod =0, No compare
CmpMethod =1, CmpValue=Counter (Directionless)
CmpMethod =2, CmpValue=Counter (+Dir)
CmpMethod =3, CmpValue=Counter (-Dir)
Содержание cPCI-8168
Страница 4: ......
Страница 10: ...vi List of Figures...
Страница 29: ...Installation 19 2 9 Overview of CN3 CN6...
Страница 31: ...Installation 21 2 11 Switch Setting...
Страница 124: ...114 Function Library Src Counter source Return Code ERR_NoError Value Meaning 0 External Feedback 1 Command pulse...
Страница 134: ...124 Function Library Return Code ERR_NoError ERR_SpeedError ERR_PChangeSlowDownPointError ERR_MoveRatioError...
Страница 155: ...Function Library 145 12 At FH speed maximum velocity 13 In deceleration 14 Waiting for INP signal 15 Reserved...