5.3.4Pulse I/O and INT factor configuration form
In this form users can set the configuration of pulse input/output,
move ration, and INT factor.
A. Pulse Output Mode
: Select the output mode of pulse signal
(OUT/ DIR). The related function call is _8168_set_pls_outmode().
B. Pulse Input
: Set the configurations of Pulse input signal(EA/
EB). The related function call is _8168_set_pls_iptmode(),
_8168_set_feedback_src().
C. Move Ratio
: Set the move ratio (feedback / pulse command)for
current target axis. The value should not be ‘0’. The related func-
tion call is _8168_set_move_ratio().
D. INT Factor
: Select factors to initiate the event int. The related
function call is _8168_set_int_factor().
E. Next Axis
: Click this button to change operating axis.
F. Save Config
: Click this button to save current configuration to
8168.ini.
G.
Switch Operate form (5.3.2)
H.
Switch to Interface I/O configuration form (5.3.3)
I. Back
: Click this button to go back “main” form.