148
Function Library
alm_mode=0, motor immediately stops(Default)
alm_mode=1, motor decelerates then stops.
el_mode
: reacting modes when receiving EL signal.
el_mode=0, motor immediately stops.(Default)
el_mode=1, motor decelerates then stops.
inp_enable
: INP function enable/disable
inp_enable=0, Disabled (Default)
inp_enable=1, Enabled
inp_logic
: setting of active logic for INP signal
inp_logic=0, active LOW.
inp_logic=1, active HIGH.
erc_logic
: setting of active logic for ERC signal
erc_logic=0, active LOW.
erc_logic=1, active HIGH.
erc_on_time
: Setting of time length of ERC active
erc_on_time=012us
erc_on_time=1102us
erc_on_time=2409us
erc_on_time=31.6ms
erc_on_time=413ms
erc_on_time=552ms
erc_on_time=6104ms
on_off
: ON-OFF state of SVON signal
on_off = 0 , ON
on_off = 1 , OFF
enable
: Enable/disable the SD signal.
enable=0, Disabled (Default)
enable=1, Enabled