Section 11 – Testing the System
11-3
Other Displays (fixed-word keypad displays are in parentheses)
Busy-Standby (dI). If this remains displayed for more than 1 minute, the system is disabled.
Modem Comm (CC) The system is in communication with the central station for change of function or status verification.
Comm. Failure (FC) A communication failure has occurred.
Open Circuit (OC) The keypad is not receiving signals from the control and sees an open circuit.
Long Rng Trbl (bF) Backup LRR communication failure.
TO THE INSTALLER
Regular maintenance and inspection (at least annually) by the installer and frequent testing by the user are vital to
continuous satisfactory operation of any alarm system.
The installer should assume the responsibility of developing and offering a regular maintenance program to the user
as well as acquainting the user with the proper operation and limitations of the alarm system and its component parts.
Recommendations must be included for a specific program of frequent testing (at least weekly) to insure the system's
proper operation at all times.
Troubleshooting Guide
CONTROL PANEL
SYMPTOM
POSSIBLE CAUSE
REMEDY
1.
AC POWER light off or
NO
AC
displayed
1a. Interrupted primary AC power.
1a. Check transformer connection and power
line circuit breaker.
2. Digital
communicator
message not being received.
2a. Control in Test mode.
2b. Telephone connection not secure.
2c. Digital
communicator
malfunctioning.
2d. Telephone number in program needs
prefix or access code.
2e. Telephone call to central monitoring
station requires operator assistance.
2a. Remove from Test mode.
2b. Check all connections.
2c. Check with a different VISTA-10SE.
2d. Program prefix or access code into the
control.
2e. System cannot work in this situation.
3.
Does not arm properly.
3a. READY light not on.
3a. Check for faulted zone(s) by pressing [
✱
]
and make intact, or use Bypass arming,
if desired.
4. VISTA-10SE
doesn't
respond to keystrokes on
keypad.
4a. CC or MODEM COMM displayed.
4b. dI or SYSTEM BUSY displayed.
4c. E4 or E8 displayed.
4d. Keypad address setting incorrect.
4a. System is in communication with
downloader at Central Station. Wait
until download session is finished.
4b. System has just been powered and is in its
1-minute initialization.To bypass this time,
press [#] + [0].
4c. More zones have been programmed than
the zone expansion modules can
handle.Delete some zones or use a higher
capability RF receiver.
4d. Keypads must be set for address 31 (non-
addressable mode).
Содержание VISTA-10ES
Страница 24: ...VISTA 10SE Installation and Setup Guide 3 4...
Страница 34: ...VISTA 10SE Installation and Setup Guide 4 10...
Страница 44: ...VISTA 10SE Installation and Setup Guide 5 10...
Страница 58: ...VISTA 10SE Installation and Setup Guide 9 4...
Страница 66: ...VISTA 10SE Installation and Setup Guide 11 6...
Страница 68: ...VISTA 10SE Installation and Setup Guide 12 2...
Страница 80: ...1 9 l N7227V6 7 01 165 Eileen Way Syosset New York 11791 Copyright 2001 PITTWAY CORPORATION...