Section 6 - Output Device Programming
6–3
PROMPT
VALID ENTRIES
EXPLANATION
Output Device Displays
E n t e r R e l a y N o .
( 0 0 = Q u i t ) 0 1
Enter Relay No.
[
✱
]
to continue
Upon pressing
✱
80, this screen will appear. Enter the Relay
Number 01, 02, 03, or 04 for a 4204 (or 00 to end these entries).
The [
✱
] key is used to accept an entry and advance to the next
prompt. The [#] key is used to revert back to the last question to
check or change an entry. Press [
✱
] to go forward again.
02 A EV ZL ZT –
STT 0 0 0 00 –
START Summary Screen
[
✱
]
key to continue
This screen displays a summary of the current Relay START
programming
(for this example, relay 02 has been selected).
02 A EV ZL ZT –
STP – – 0
00 –
STOP Summary Screen
[
✱
]
to continue
This screen displays a summary of the current Relay STOP
programming.
0 2 R e l a y A c t i o n
N o R e s p o n s e
0
Response To Fault
[
✱
]
to continue
Enter the desired relay action as follows:
0 = No response 2 = Close and Stay Closed
1 = Close for 2 seconds 3 = Continuous Pulse on & off
(1 sec ON, 1 sec OFF)
0 2 S t a r t E v e n t
N o t U s e d
0
START Event
[
✱
]
to continue
Enter the event to START the relay:
0 = Not used; 2 = Fault; 1 = Alarm; 3 = Trouble
A zone list must be used in conjunction with an event. If a zone
type/system operation is to be used instead of an event, enter 0.
0 2 S t a r t : Z n L i s t
N o L i s t
0
START by Zone List
[
✱
]
to continue
If a zone list will be used to START the relay action, enter the
zone list number (to be programmed in field •81): 1, 2, or 3. If
not used, enter 0.
02 Start:
Zn Typ
No Used
00
START by Zone Type
[
✱
]
to continue
If a zone type or system operation will be used to START the
relay action, enter the appropriate two-digit code (see table that
follows). If not, enter 00.
CHOICES FOR ZONE TYPES
00 = Not Used
05 = Trouble Day/Alarm Night
08 = 24-Hr Aux
01 = Entry/Exit
06 = 24-Hr Silent
09 = Fire
03 = Perimeter
07 = 24-Hr Audible
10 = Interior w/Delay
04 = Interior Follower
CHOICES FOR SYSTEM OPERATION
20 = Arming–STAY
33 = Any Burglary Alarm
39 = Any Fire Alarm
21 = Arming–AWAY
34 = Code + # + 7 Key Entry
40 = Bypassing
22 = Disarming (Code + OFF)
35 = Code + # + 8 Key Entry
41 = AC Power Failure
31 = End of Exit Time
36 = At Bell Timeout**
42 = System Low Bat
32 = Start of Entry Time
38 = Chime
58 = Duress
**Or at Disarming, whichever occurs earlier.
Содержание VISTA-10ES
Страница 24: ...VISTA 10SE Installation and Setup Guide 3 4...
Страница 34: ...VISTA 10SE Installation and Setup Guide 4 10...
Страница 44: ...VISTA 10SE Installation and Setup Guide 5 10...
Страница 58: ...VISTA 10SE Installation and Setup Guide 9 4...
Страница 66: ...VISTA 10SE Installation and Setup Guide 11 6...
Страница 68: ...VISTA 10SE Installation and Setup Guide 12 2...
Страница 80: ...1 9 l N7227V6 7 01 165 Eileen Way Syosset New York 11791 Copyright 2001 PITTWAY CORPORATION...