VISTA-10SE Installation and Setup Guide
5–2
PROMPT
VALID ENTRIES
EXPLANATION
È
Zone Number
10 Zone Type
Perimeter 03
Zone Type
Ç
Zone Type (ZT)
00-10, 20-23 = Zone type
(refer to table)
[
✱
]
to continue
Enter the Zone Type response (or change it, if necessary).
Each zone must be assigned to a zone type, which defines the way
in which the system responds to faults in that zone.
Enter the Zone Type code (or change it, if necessary). Zone types
are listed below.
NOTE: If you enter 00,
Delete Zone ?
is displayed.
00 = Not used
01 = Entry/Exit
02 = Not used
03 = Perimeter
04 = Interior Follower
05 = Trouble Day/Alarm Night
06 = 24-Hr Silent
07 = 24-Hr Audible
08 = 24-Hr Aux
09 = Fire
10 = Interior w/Delay
20 = Arm–STAY*
21 = Arm–AWAY*
22 = Disarm*
23 = No Alarm**
* 5800 button-type transmitters only
** Used with relays typically when no alarm response is required
10 Report Code
1st 01 2nd 00 10
Report Code (RC)
[
✱
]
to continue
Enter the report code. This consists of 2 hexadecimal digits, each in
turn consisting of 2 numerical digits. For example, for a report code
of “10,” enter 01 and 00. Refer to SECTION 9: System
Communication for more information about report codes and
report code formats.
NOTE: Report codes are defaulted to 10 for use with CID
reporting.
10 INPUT TYPE
RF TRANS 3
Input Device type (IN)
3 = RF (supervised RF
transmitter)
4 = UR (unsupervised RF
transmitter)
5 = BR (Button-type RF
transmitter unsupervised)
[
✱
]
to continue
For the built-in hardwired zones 01-06, the Input Device type is
automatically displayed as HW and cannot be edited.
For wireless zones 10 and higher, inputs can be entered as:
“RF” (Supervised RF) Type send periodic check-in signals, as
well as fault, restore, and low battery signals. The transmitter must
remain within the receiver's range.
“UR” (Unsupervised RF Type send all the signals that the “RF”
type does, but the control does not supervise the check-in signals.
The transmitter may, therefore, be carried off-premises.
“BR” (Unsupervised Button RF Type only send fault signals.
They do not send low battery, restore, or check-in signals. The
transmitter may be carried off-premises.
10 INPUT S/N L
A 0 2 2 - 4 0 6 4
1
Note: The [A] and [B]
keys may be used to
move the cursor to the
right (A) or left (B) within
the serial number field,
thus allowing you to
correct any entry errors
that may have been
made.
Serial number Entry
[
✱
]
to continue
Used only when enrolling wireless transmitters.
a.
Transmit an open and close sequence. If using a button-type
transmitter, press and release the button;
OR
b.
Manually enter the 7-digit serial number printed on the label of
the transmitter, using the alpha display keypad;
OR
c.
To copy the serial number previously enrolled (used when
programming a transmitter with several input loops), simply
press key [C].
The cursor then moves to the “L.” You can edit the loop number, if
necessary as follows.
Содержание VISTA-10ES
Страница 24: ...VISTA 10SE Installation and Setup Guide 3 4...
Страница 34: ...VISTA 10SE Installation and Setup Guide 4 10...
Страница 44: ...VISTA 10SE Installation and Setup Guide 5 10...
Страница 58: ...VISTA 10SE Installation and Setup Guide 9 4...
Страница 66: ...VISTA 10SE Installation and Setup Guide 11 6...
Страница 68: ...VISTA 10SE Installation and Setup Guide 12 2...
Страница 80: ...1 9 l N7227V6 7 01 165 Eileen Way Syosset New York 11791 Copyright 2001 PITTWAY CORPORATION...