Section 2 – Installing the Control & Peripherals
2-11
TERMINALS
ON CONTROL
EARTH GROUND
INCOMING TELECOM LINE
HANDSET
TIP
RING
RJ31X
JACK
PLUG
DIRECT
CONNECT
CORD
TIP
RING
GROUND
PREMISES
PHONES
BROWN (TIP)
GREY (RING)
GREEN (TIP)
RED (RING)
17
18
19
20
21
INCOMING
TELECOM
LINE
V10SE-024-V0
Figure 2-12. Standard Telephone Line Connections
Long-Range Radio Connections
If output to Long-Range Radio (LRR) is selected, all
messages that are programmed to go to the primary
telephone line receiver are also sent to any LRR that
can operate in ECP mode.
Wiring Connections
Connect the data in/data out terminals and voltage input
terminals of the Long Range Radio to the control's keypad
connection points, terminals.
For complete information, see the manual that
accompanies the radio.
NOTES:
•
Use 7720PLUS, 7820, or 7835C Long Range Radios
•
Messages are sent in Contact ID
®
format (not
affected by entry in field
✱
46).
You must enable field
✱
27, OUTPUT TO LONG-
RANGE RADIO, if this feature is to function.
UL
For UL installations, Long-Range Radio must be
disabled (
✱
27 = 0).
The VISTA-10SE control panel features Dynamic
Signaling Delay (DSD) and Dynamic Signaling Priority
(DSP) message reporting when Long-Range Radio is
used. Refer to field
✱
93 in SECTION 4: Data Field
Programming for further details.
Audio Alarm Verification (AAV) Connections
Wiring Connections
Refer to the connection diagrams below. Figure 2-13
shows connections when a 4285/4286 VIP (Phone)
Module is not used, Figure 2-14 shows connections
when the 4285/4286 is used.
UL
The AAV option cannot be used in UL
installations.
NOTES:
•
Suggested AAV Module: Eagle 1250
•
To
enable
the AAV feature, enter option “4” in field
✱
91
Option Selection (AAV)
•
Select Contact ID
®
report format to primary phone
number
•
Program alarm reports for the primary phone number.
•
You must connect a 4204 relay module when using
an AAV unit, as shown in the following diagrams.
Содержание VISTA-10ES
Страница 24: ...VISTA 10SE Installation and Setup Guide 3 4...
Страница 34: ...VISTA 10SE Installation and Setup Guide 4 10...
Страница 44: ...VISTA 10SE Installation and Setup Guide 5 10...
Страница 58: ...VISTA 10SE Installation and Setup Guide 9 4...
Страница 66: ...VISTA 10SE Installation and Setup Guide 11 6...
Страница 68: ...VISTA 10SE Installation and Setup Guide 12 2...
Страница 80: ...1 9 l N7227V6 7 01 165 Eileen Way Syosset New York 11791 Copyright 2001 PITTWAY CORPORATION...