VISTA-10SE Installation and Setup Guide
3-2
Type 05
Trouble by Day/
Alarm by Night
Zone type 05 is usually assigned to a zone that contains foil-protected doors or windows; or
covers a sensitive area (e.g., stock room, drug supply room, etc.) It can also be used on a
sensor or contact in an area where immediate notification of an entry is desired.
•
Provides an instant alarm when armed in AWAY, STAY, INSTANT, or MAXIMUM
(night) mode.
•
Provides a latched trouble sounding from the keypad and, if desired, a central station
report during the disarmed state (day).
Type 06
24-hour Silent
Alarm
Zone type 06 is usually assigned to a zone containing an Emergency button.
•
Sends a report to the central station but provides no keypad display or sounding.
Type 07
24-hour Audible
Alarm
Zone type 07 is usually assigned to a zone containing an Emergency button.
•
Sends a report to the central station, and provides alarm sounds externally and at the
keypad.
Type 08
24-hour
Auxiliary Alarm
Zone type 08 is usually assigned to a zone containing a button for use in personal
emergencies or to a zone containing monitoring devices (e.g., water or temperature sensors,
etc.).
•
Sends a report to the central station and provides an alarm sound at the keypad. (No bell
output is provided and there is no keypad timeout.)
Type 09
Supervised Fire
Zone type 09 can be assigned to any wireless zone used as a fire zone. This zone type is
always active and cannot be bypassed.
•
Bell output will pulse when this zone type is alarmed.
Type 10
Interior w/Delay
Zone type 10 is bypassed when the panel is armed in the STAY or INSTANT mode.
•
Entry delay #1 (with programmed entry time) when armed in the AWAY mode.
•
Entry delay begins whenever sensors in this zone are violated, regardless of whether an
entry/exit delay zone was tripped first.
•
No entry delay when armed in the MAXIMUM mode.
Exit delay regardless of the arming mode selected.
Type 20
Arm–STAY
Zone type 20 is a special-purpose zone type used with 5800 Series wireless pushbutton
transmitters.
•
Exit delay regardless of the arming mode selected.
•
System is armed in the STAY mode when the zone is activated.
Zone number is sent to the central station as a user number when arming or disarming.
Type 21
Arm–AWAY
Zone type 21 is a special-purpose zone type used with 5800 Series wireless pushbutton
units.
•
System is armed in the AWAY mode when the zone is activated.
•
Zone number is sent to the central station as a user number when arming or disarming.
Type 22
Disarm
Zone type 22 is a special-purpose zone type used with 5800 Series wireless pushbutton.
•
Disarms the system when the zone is activated.
Type 23
No Alarm
Response
Zone type 23 can be used when the action of a relay is desired, but with no accompanying
alarm (e.g., a front or back door light being turned on or off).
Содержание VISTA-10ES
Страница 24: ...VISTA 10SE Installation and Setup Guide 3 4...
Страница 34: ...VISTA 10SE Installation and Setup Guide 4 10...
Страница 44: ...VISTA 10SE Installation and Setup Guide 5 10...
Страница 58: ...VISTA 10SE Installation and Setup Guide 9 4...
Страница 66: ...VISTA 10SE Installation and Setup Guide 11 6...
Страница 68: ...VISTA 10SE Installation and Setup Guide 12 2...
Страница 80: ...1 9 l N7227V6 7 01 165 Eileen Way Syosset New York 11791 Copyright 2001 PITTWAY CORPORATION...