11-1
S E C T I O N 1 1
Testing the System
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Local Tests
After the security system installation is complete, test the system as follows:
1.
With the system in the disarmed state, check that all zones are intact. If a NOT READY message is displayed, press the [
✱
] key to
display the faulted zone(s). Restore faulted zone(s) if necessary, so that the READY message is displayed.
2.
Enter the security code and press the TEST [5] key.
The external sounder will sound for 1 second. If the backup battery is discharged or missing, the sounder may not turn on and a
LOW BATTERY report will be transmitted with a TEST report.
Note that the keypad will beep once every 40 seconds as a reminder that the system is in the Test mode.
3.
Fault and restore every sensor individually to assure that it is being monitored by the system. Each time a protection zone is
faulted, the keypad will sound 3 beeps, and the identification of each faulted protection zone should appear on the keypad display.
NOTE: For 5800 wireless systems, triggering a zone set to Arm-AWAY, Arm-STAY, or Disarm will take the system out of the
TEST mode and cause that action.
4. Walk in front of any interior motion detectors (if used) and listen for the required sound as movement is detected. The
identification of the detector should appear on the display when it is activated.
NOTE: Wireless motion detectors (passive infrared units) will send signals out only if they have been inactive for 3 minutes.
5.
Follow the manufacturer's instructions to test all smoke detectors, to ensure that all are functioning properly. The identification of
each detector should appear on the display when each is activated.
6.
Turn off the test mode by entering the security code and pressing the OFF [1] key.
Communication Tests
Alarm messages will be sent to the central station during the following tests. Notify CS personnel in advance that
tests will be in progress.
1.
Arm the system (STAY) and fault one or more perimeter zones. After 15 seconds, silence alarm sounder(s) by entering the security
code and pressing the OFF [1] key.
Arm the system AWAY, and check the Entry/Exit zones for the programmed exit and entry delays.
2.
Check the keypad-initiated alarms that are in the system by using the Panic keys (or key pairs on some keypads). If a key (or key
pair) has been programmed for audible emergency, the keypad will emit a steady alarm sound, and ALARM and zone number will
be displayed.
If a key (or key pair) has been programmed for silent emergency, there will be no audible alarms or displays, but a report will be
sent to the central station.
If a key (or key pair) has been programmed for fire, the keypad and external sounder will emit an interrupted alarm sound, and
ALARM, FIRE and zone number will be displayed.
Silence alarms by entering the security code and pressing the OFF [1] key.
3.
If Output Relay Units have been installed, test their programmed action.
4.
Notify the central station when all tests are finished, and verify results with them.
To test the wireless part of the system and the RF Receiver, perform the two following tests: Transmitter Sniffer Mode and
Go/NoGo Test Mode.
Transmitter Sniffer Mode
Make sure the system is disarmed before trying to enter this mode.
1. Key
Installer Code + [#] + [3]. This initiates a procedure that checks that all 5800 Series transmitters have been properly
programmed.
NOTE: If the communicator is in the process of sending a report to the central station, the system will not go into the Sniffer mode. If
so, wait a few minutes, and try again.
The keypad displays all zone numbers of wireless units programmed into the system. As the system receives a signal from each of the
transmitters, the zone number of that transmitter disappears from the display. The transmitter codes may be checked upon
installation, or in an installed system.
All the wireless zone numbers should disappear after about 1-1/2 hours.
NOTE: Any transmitter that is not properly entered into the system will not turn off its zone number.
2.
Exit the Transmitter Sniffer mode by keying Installer code + OFF [1] key.
Содержание VISTA-10ES
Страница 24: ...VISTA 10SE Installation and Setup Guide 3 4...
Страница 34: ...VISTA 10SE Installation and Setup Guide 4 10...
Страница 44: ...VISTA 10SE Installation and Setup Guide 5 10...
Страница 58: ...VISTA 10SE Installation and Setup Guide 9 4...
Страница 66: ...VISTA 10SE Installation and Setup Guide 11 6...
Страница 68: ...VISTA 10SE Installation and Setup Guide 12 2...
Страница 80: ...1 9 l N7227V6 7 01 165 Eileen Way Syosset New York 11791 Copyright 2001 PITTWAY CORPORATION...