Section 5 - Zone Programming
5–7
PROMPT
VALID ENTRIES
EXPLANATION
1 0 Z o n e T y p e
Zone Disabled
00
Zone Type
[
✱
]
to continue
4. Enter
00. This sets the zone type to Zone Disabled.
The prompt at left appears confirming 00 entry in previous step.
D e l e t e Z o n e ?
0 = No, 1 = Yes 0
Delete Zone
0 = no (see explanation)
1 = yes (see explanation)
5. The prompt at left asks if you want to delete the zone.
1 (Yes) permanently removes the zone from the system, while
0 (No) disables it but retains all data except the original zone
type. You can then go back to this zone later and put back an
active zone type to reenable it.
6.
At Enter Zn Num. prompt, press 00 to exit, followed by
✱
99 to leave programming mode.
A serial number that has been entered for a 5800 system will not
be deleted if the zone is temporarily disabled by answering “No” to
this last prompt. If only the transmitter is to be replaced, it can be
accomplished in To Delete a Transmitter Serial Number
procedure that follows.
To Delete a Transmitter Serial Number
The abbreviated procedure that follows can be used to delete and replace a transmitter serial number from a zone, using
the
✱
56 Mode.
SET TO CONFIRM?
0 = NO 1 = YES 0
Set to Confirm
0 = no
1 = yes
1.
Enter the programming mode:
Key Installer Code + 8 + 0 and press
✱
56.
2.
The prompt at left appears. Select 1 = yes.
3.
Enter zone number of transmitter to be deleted.
Example = zone number 10.
10 INPUT S/N: L
A 0 2 2 - 4 0 6 4 1
4. Press
[
✱
] repeatedly until the prompt at left appears.
This is the transmitter serial number and loop number that is
presently programmed for this zone.
5. Enter
0 in the flashing loop number field.
The serial number changes to all 0's. The other programmed
values for that zone are not deleted. This allows you to enroll
a new transmitter in its place.
10 INPUT S/N: L
A 0 0 0 - 0 0 0 0 0
Serial number Entry and
Loop Number Entry
6. Press
[
✱
] to accept the 0 loop entry.
If you want to replace the serial number continue to step 7. A
display for the new transmitter number appears.
If you do not want to replace the transmitter, skip to step 11
by pressing the [
✱
] key repeatedly until the 00 to "Quit"
prompt is displayed.
10 INPUT S/N:
L
AXXX-XXXX X
[
✱
]
to continue
7.
Key the transmitter (or manually insert the new transmitter
serial number). The new transmitter serial number replaces
the X’s in the display at left.
Use the A or B key to move the cursor to the right or left
respectively in the serial number to correct any wrong
entries.
8. Press
[
✱
] key to position the cursor in the loop entry position.
Insert the loop number connected with this new transmitter
serial number. Loop 1 is the default loop.
10 INPUT S/N:
L
A 0 2 4 - 3 9 3 8 1s
Change Verification
The new display appears with a small “s” next to the loop
number to indicate that the new transmitter serial number
has been learned.
9.
Press the [
✱
] key repeatedly until “Enter Zone Number”
prompt is displayed.
To exit, enter 00.
10. Press
✱
99 to exit the Programming mode.
Содержание VISTA-10ES
Страница 24: ...VISTA 10SE Installation and Setup Guide 3 4...
Страница 34: ...VISTA 10SE Installation and Setup Guide 4 10...
Страница 44: ...VISTA 10SE Installation and Setup Guide 5 10...
Страница 58: ...VISTA 10SE Installation and Setup Guide 9 4...
Страница 66: ...VISTA 10SE Installation and Setup Guide 11 6...
Страница 68: ...VISTA 10SE Installation and Setup Guide 12 2...
Страница 80: ...1 9 l N7227V6 7 01 165 Eileen Way Syosset New York 11791 Copyright 2001 PITTWAY CORPORATION...