6240B DC Voltage Current Source/Monitor Operation Manual
5.2.2 Operations in Pulse Source Mode
5-10
5.2.2
Operations in Pulse Source Mode
The following table shows operations in the pulse source mode.
Table 5-3 Operations in Pulse Source Mode (1/2)
Operational
condition
Trigger mode
Description
Operation
Remarks
Operate ON
AUTO
Executes continu-
ous measurement
with the setting
period time Tp.
Tp: Period time
Tw: Pulse width
Td: Measurement delay time
Tds:Source delay time
Tm: Measurement time
(Integration time +
Measurement data
processing time)
Tcn: Operate processing time
Trc: Range change processing
time
HOLD
Executes mea-
surement after
trigger input.
Changing the
source value
AUTO
Source value
changing does not
induce range
changing.
HOLD
Standby
Operate
Tp
Tp
Tw
Tw
Td
Tm
Td
Tm
Tcn
Tds
Tds
COMPLETE OUT [FRONT]
COMPLETE OUT [END]
COMPLETE OUT [HI/GO/LO]
SYNC OUT
Standby
Tp
COMPLETE OUT [FRONT]
TRIGGER IN
Operate
Tcn
Tw
Td
Tm
Tds
Measurement
trigger
SYNC OUT
COMPLETE OUT [HI/GO/LO]
COMPLETE OUT [END]
Tp
Tp
Tw
Tw
Td
Tm
Tm
Td
Tds
Tds
Base value
Source value
change processing
(Not change the range)
COMPLETE OUT [FRONT]
SYNC OUT
COMPLETE OUT [HI/GO/LO]
COMPLETE OUT [END]
Source value
change processing
(Not change the range)
Td
COMPLETE OUT [FRONT]
COMPLETE OUT [HI/GO/LO]
COMPLETE OUT [END]
Tp
Tw
Tm
Tds
Base value
Changes the source value
(Not change the range)
SYNC OUT
TRIGGER IN
Measurement