[E33]/W
Port 1 No DL test tone (Band 2).
Hub/Port DL path gain is low.
[E34]/W
Port 2 No DL test tone (Band 2).
Hub/Port DL path gain is low.
[E35]/W
Port 3 No DL test tone (Band 2).
Hub/Port DL path gain is low.
[E36]/W
Port 4 No DL test tone (Band 2).
Hub/Port DL path gain is low.
[E37]/W
Port 5 No DL test tone (Band 2).
Hub/Port DL path gain is low.
[E38]/W
Port 6 No DL test tone (Band 2).
Hub/Port DL path gain is low.
[E39]/W
Port 7 No DL test tone (Band 2).
Hub/Port DL path gain is low.
[E40]/W
Port 8 No DL test tone (Band 2).
Hub/Port DL path gain is low.
[E41]/W
Port 1 No DL test tone (Band 3).
Hub/Port DL path gain is low.
[E42]/W
Port 2 No DL test tone (Band 3).
Hub/Port DL path gain is low.
[E43]/W
Port 3 No DL test tone (Band 3).
Hub/Port DL path gain is low.
[E44]/W
Port 4 No DL test tone (Band 3).
Hub/Port DL path gain is low.
[E45]/W
Port 5 No DL test tone (Band 3).
Hub/Port DL path gain is low.
[E46]/W
Port 6 No DL test tone (Band 3).
Hub/Port DL path gain is low.
[E47]/W
Port 7 No DL test tone (Band 3).
Hub/Port DL path gain is low.
[E48]/W
Port 8 No DL test tone (Band 3).
Hub/Port DL path gain is low.
[E49]/W
Port 1 DL path loss is high.
If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[E50]/W
Port 2 DL path loss is high.
If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[E51]/W
Port 3 DL path loss is high.
If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[E52]/W
Port 4 DL path loss is high.
If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[E53]/W
Port 5 DL path loss is high.
If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[E54]/W
Port 6 DL path loss is high.
If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[E55]/W
Port 7 DL path loss is high.
If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[E56]/W
Port 8 DL path loss is high.
If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[E57]/W
Port 1 UL path loss is high.
Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem is on more than
one port, replace the Hub, otherwise replace the RAU.
[E58]/W
Port 2 UL path loss is high.
Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem is on more than
one port, replace the Hub, otherwise replace the RAU.
Table C-7
Warning/Status Message for Expansion Hubs (continued)
Message
Number
/Default
Description
Reason/Action
Содержание InterReach Fusion
Страница 8: ...CONFIDENTIAL 6 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 12: ...CONFIDENTIAL 4 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 16: ...CONFIDENTIAL 4 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 205: ...Help Hot Line U S only 1 800 530 9960 A 3 D 620610 0 20 Rev D CONFIDENTIAL Figure A 2 CommScope 2279V for RG 6...
Страница 214: ...A 12 InterReach Fusion Installation Operation and Reference Manual CONFIDENTIAL D 620610 0 20 Rev D...
Страница 238: ...C 20 InterReach Fusion Installation Operation and Reference Manual CONFIDENTIAL D 620610 0 20 Rev D...