Help Hot Line (U.S. only):
1-800-530-9960
C-11
D-620610-0-20 Rev D
CONFIDENTIAL
Table C-5
Warnings/Status Messages for Main Hubs
Message
Number/
Default
Description
Reason/Action
[M01]/S
Fan 1 failure.
Check the fan for rotation, air flow blockage, and dust.
Replace the Hub on high temperature warning.
[M02]/S
Fan 2 failure.
Check the fan for rotation, air flow blockage, and dust.
Replace the Hub on high temperature warning.
[M03]/S
54 VDC Pwr Supply Fan failure.
Check the fan for rotation, air flow blockage, and dust.
Replace the Hub on high temperature warning.
[M04]/W
5 VDC Monitor.
DC power out of range, replace the Hub.
[M05]/W
9 VDC Monitor.
DC power out of range, replace the Hub.
[M06]/W
54 VDC Monitor.
DC power out of range, replace the Hub.
[M07]/W
3 VDC Monitor.
DC power out of range, replace the Hub.
[M08]/W
12 VDC Monitor.
DC power out of range, replace the Hub.
[M09]/W
Temperature High.
Reduce ambient temperature, check for air flow blockage,
fan rotation.
[M10]/W
-5 VDC Monitor.
DC power is out of range, replace the Hub.
[M11]/W
High laser current.
Output laser failure possible, replace the Hub when possi-
ble.
[M12]/W
DL path loss is too high
Replace the Hub.
[M13]/S
Low input optical (Port 1).
Check the uplink fiber.
[M14]/S
Low input optical (Port 2).
Check the uplink fiber.
[M15]/S
Low input optical (Port 3).
Check the uplink fiber.
[M16]/S
Low input optical (Port 4).
Check the uplink fiber.
[M17]/S
Hardware failure (Test Tone PLL
Band 1).
Unable to perform DL system test.
[M18]/S
Hardware failure (Test Tone Too
High Band 1).
Unable to perform DL system test.
[M19]/S
Hardware failure (Test Tone Too
Low Band 1).
Unable to perform DL system test.
[M20]/W
Overdrive limiter active (Band 1).
Reduce input signal power to avoid potential component
damage.
[M21]/W
CEMark limiter at maximum
(Band 1).
Reduce input signal power to avoid drop in system gain.
[M22]/W
No DL test tone (Band 1).
Hub DL gain is low.
[M23]/S
No UL test tone (Band 1).
Hub UL path gain is low.
[M24]/S
Problem detected in the system.
Contact ADC Support for more information.
[M25]/S
Hardware failure (Test Tone PLL
Band 2).
Unable to perform DL system test. Replace the hub when
possible.
[M26]/S
Hardware failure (Test Tone Too
High Band 2).
Unable to perform DL system test. Replace the hub when
possible.
[M27]/S
Hardware failure (Test Tone Too
Low Band 2).
Unable to perform DL system test. Replace the hub when
possible.
[M28]/W
Overdrive limiter active (Band 2).
Reduce input signal power to avoid potential component
damage.
[M29]/W
CEMark limiter at maximum
(Band 2).
Reduce input signal power to avoid drop in system gain.
Содержание InterReach Fusion
Страница 8: ...CONFIDENTIAL 6 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 12: ...CONFIDENTIAL 4 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 16: ...CONFIDENTIAL 4 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 205: ...Help Hot Line U S only 1 800 530 9960 A 3 D 620610 0 20 Rev D CONFIDENTIAL Figure A 2 CommScope 2279V for RG 6...
Страница 214: ...A 12 InterReach Fusion Installation Operation and Reference Manual CONFIDENTIAL D 620610 0 20 Rev D...
Страница 238: ...C 20 InterReach Fusion Installation Operation and Reference Manual CONFIDENTIAL D 620610 0 20 Rev D...