Help Hot Line (U.S. only):
1-800-530-9960
5-5
D-620610-0-20 Rev D
CONFIDENTIAL
Remote Access Unit Connectors
* Exceeding the distance of copper-clad cable will result in the attached RAU becoming non-functional. If
the distance of a cable run is at its maximum and is of concern, ADC recommends the use of solid copper
cable to ensure successful operation.
5.2
Remote Access Unit Connectors
5.2.1
50 Ohm Type-N Connector
The RAU has one female type-N connector. The connector is a duplexed RF
input/output port that connects to a standard 50
:
passive antenna using coaxial cable.
5.2.2
75 Ohm Type-F Connector
The RAU has one type-F female connector that connects it to a Fusion Hub using
CATV 75 Ohm cable. Use RG-59, 6, or 11 solid copper center conductor cables.
Table 5-3
System Gain (Loss) Relative to CATV Cable Length for 800/900/1900
RAUs
Cable
Type
Comm-
Scope
Part
Number
Plenum
Rated
Solid
Copper
Conductor
Copper
Clad
Conductor
Zero-loss
RF
Maximum
Length
(meters)
Distance
Where
RF is
10dB
Below
Input RF
(meters)
RG-59
2065V
Yes
X
150
210
2022V
Yes
X
80
80*
5572R
No
X
70
70*
5565
No
X
150
210
RG-6
2279V
Yes
X
170
230
2275V
Yes
X
115
115*
5726
No
X
110
110*
5765
No
X
170
230
RG-11
2293K
Yes
X
275
375
2285K
Yes
X
240
240*
5913
No
X
240
240*
Содержание InterReach Fusion
Страница 8: ...CONFIDENTIAL 6 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 12: ...CONFIDENTIAL 4 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 16: ...CONFIDENTIAL 4 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 205: ...Help Hot Line U S only 1 800 530 9960 A 3 D 620610 0 20 Rev D CONFIDENTIAL Figure A 2 CommScope 2279V for RG 6...
Страница 214: ...A 12 InterReach Fusion Installation Operation and Reference Manual CONFIDENTIAL D 620610 0 20 Rev D...
Страница 238: ...C 20 InterReach Fusion Installation Operation and Reference Manual CONFIDENTIAL D 620610 0 20 Rev D...