Help Hot Line (U.S. only):
1-800-530-9960
C-13
D-620610-0-20 Rev D
CONFIDENTIAL
[M66]/S
Problem detected in the Hub.
Contact ADC Support for more information.
[M67]/S
Problem detected in the Hub.
Contact ADC Support for more information.
[M68]/S
No UL test tone (Port 4/Band 1).
Hub/Port UL path gain is low.
[M69]/S
No UL test tone (Band 2).
Hub/Port UL path gain is low.
[M70]/S
No UL test tone (Port 2/Band 2).
Hub/Port UL path gain is low.
[M71]/S
No UL test tone (Port 3/Band 2).
Hub/Port UL path gain is low.
[M72]/S
No UL test tone (Port 4/Band 2).
Hub/Port UL path gain is low.
[M73]/S
No UL test tone (Band 3).
Hub/Port UL path gain is low.
[M74]/S
No UL test tone (Port 2/Band 3).
Hub/Port UL path gain is low.
[M75]/S
No UL test tone (Port 3/Band 3).
Hub/Port UL path gain is low.
[M76]/S
No UL test tone (Port 4/Band 3).
Hub/Port UL path gain is low.
[M77]/S
Problem detected in the Hub.
Contact ADC Support for more information.
[M78]/S
Problem detected in the Hub.
Contact ADC Support for more information.
[M79]/S
Problem detected in the Hub.
Contact ADC Support for more information.
[M80]/S
Problem detected in the Hub.
Contact ADC Support for more information.
[M81]/W
Port 1 DL path loss is high.
If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[M82]/W
Port 2 DL path loss is high.
If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[M83]/W
Port 3 DL path loss is high.
If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[M84]/W
Port 4 DL path loss is high.
If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[M85]/W
Port 5 DL path loss is high.
If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[M86]/W
Port 6 DL path loss is high.
If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[M87]/W
Port 7 DL path loss is high.
If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[M88]/W
Port 8 DL path loss is high.
If the problem is on more than one port, replace the Hub.
Switch the cable connection to a different hub port until the
Hub can be replaced.
[M89]/W
Port 1 UL path loss is high.
Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem on more than one
port, replace the Hub, otherwise replace the RAU.
[M90]/W
Port 2 UL path loss is high.
Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem is on more than
one port, replace the Hub, otherwise replace the RAU.
[M91]/W
Port 3 UL path loss is high.
Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem is on more than
one port, replace the Hub, otherwise replace the RAU.
Table C-5
Warnings/Status Messages for Main Hubs (continued)
Message
Number/
Default
Description
Reason/Action
Содержание InterReach Fusion
Страница 8: ...CONFIDENTIAL 6 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 12: ...CONFIDENTIAL 4 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 16: ...CONFIDENTIAL 4 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 205: ...Help Hot Line U S only 1 800 530 9960 A 3 D 620610 0 20 Rev D CONFIDENTIAL Figure A 2 CommScope 2279V for RG 6...
Страница 214: ...A 12 InterReach Fusion Installation Operation and Reference Manual CONFIDENTIAL D 620610 0 20 Rev D...
Страница 238: ...C 20 InterReach Fusion Installation Operation and Reference Manual CONFIDENTIAL D 620610 0 20 Rev D...