Help Hot Line (U.S. only):
1-800-530-9960
7-57
D-620610-0-20 Rev D
CONFIDENTIAL
Connecting Contact Alarms to a Fusion System
Using a Base Station to Monitor Fusion
NOTE:
The BTS must be configured, by the carrier, for contact closure monitoring
prior to connecting a Fusion Main Hub to it.
When you connect a BTS to Fusion, the Fusion Main Hub is the output of the alarms
(alarm source) and the BTS is the input (alarm sense), as shown in Figure 7-33. An
interface cable is required between the daisy-chain cable and the BTS. Because BTS
alarm interface pinouts and Fusion-to-BTS distances vary, this cable is often custom
and wired on-site. Refer to Section 3.2.1 for Alarm Contact details (Normally
Closed).
Figure 7-33
Using a BTS to Monitor Fusion
NOTE:
For normally open contacts, the fault and warning contacts need to
be wired in parallel with other Main Hubs.
NOTE:
ADC does not recommend using normally open contacts.
BTS
Interface
Cable
Alarm
Sense
Alarm
Source
Alarm
Source
5-port Alarm Daisy-Chain Cable
Fusion Main Hub
(custom made, on-site)
Band 1
Band 2
Band 3
UL1
UL2
UL3
DL1
DL2
DL3
AC Power
Alarms
Band 1
Band 2
Band 3
UL1
UL2
UL3
DL1
DL2
DL3
AC Power
Alarms
Содержание InterReach Fusion
Страница 8: ...CONFIDENTIAL 6 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 12: ...CONFIDENTIAL 4 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 16: ...CONFIDENTIAL 4 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 205: ...Help Hot Line U S only 1 800 530 9960 A 3 D 620610 0 20 Rev D CONFIDENTIAL Figure A 2 CommScope 2279V for RG 6...
Страница 214: ...A 12 InterReach Fusion Installation Operation and Reference Manual CONFIDENTIAL D 620610 0 20 Rev D...
Страница 238: ...C 20 InterReach Fusion Installation Operation and Reference Manual CONFIDENTIAL D 620610 0 20 Rev D...