Estimating RF Coverage
6-18
InterReach Fusion Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620610-0-20 Rev D
Table 6-13
Approximate Radiated Distance from Antenna
for 800 MHz SMR Applications
Environment Type
Distance from Antenna
Meters
Feet
Open Environment
75
244
Moderately Open Environment
64
208
Mildly Dense Environment
56
184
Moderately Dense Environment
48
156
Dense Environment
40
131
Table 6-14
Approximate Radiated Distance from Antenna
for 850 MHz Cellular Applications
Environment Type
Distance from Antenna
Meters
Feet
Open Environment
73
241
Moderately Open Environment
63
205
Mildly Dense Environment
55
181
Moderately Dense Environment
47
154
Dense Environment
39
129
Table 6-15
Approximate Radiated Distance from Antenna
for 900 MHz SMR Applications
Facility
Distance from Antenna
Meters
Feet
Open Environment
70
230
Moderately Open Environment
60
197
Mildly Dense Environment
53
174
Moderately Dense Environment
45
148
Dense Environment
38
125
Содержание InterReach Fusion
Страница 8: ...CONFIDENTIAL 6 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 12: ...CONFIDENTIAL 4 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 16: ...CONFIDENTIAL 4 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 205: ...Help Hot Line U S only 1 800 530 9960 A 3 D 620610 0 20 Rev D CONFIDENTIAL Figure A 2 CommScope 2279V for RG 6...
Страница 214: ...A 12 InterReach Fusion Installation Operation and Reference Manual CONFIDENTIAL D 620610 0 20 Rev D...
Страница 238: ...C 20 InterReach Fusion Installation Operation and Reference Manual CONFIDENTIAL D 620610 0 20 Rev D...