C-14
InterReach Fusion Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620610-0-20 Rev D
[M92]/W
Port 4 UL path loss is high.
Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem is on more than
one port, replace the Hub, otherwise replace the RAU.
[M93]/W
Port 5 UL path loss is high.
Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem is on more than
one port, replace the Hub, otherwise replace the RAU.
[M94]/W
Port 6 UL path loss is high.
Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem is on more than
one port, replace the Hub, otherwise replace the RAU.
[M95]/W
Port 7 UL path loss is high.
Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem is on more than
one port, replace the Hub, otherwise replace the RAU.
[M96]/W
Port 8 UL path loss is high.
Check the cable for high RF loss. Switch the cable connec-
tion to a different hub port. If the problem is on more than
one port, replace the Hub, otherwise replace the RAU.
[M97]/W
Port 1 UL path exceeds maximum
gain.
If the problem is common to more than one port, replace
the Hub, otherwise check the RAU.
[M98]/W
Port 2 UL path exceeds maximum
gain.
If the problem is common to more than one port, replace
the Hub, otherwise check the RAU.
[M99]/W
Port 2 UL path exceeds maximum
gain.
If the problem is common to more than one port, replace
the Hub, otherwise check the RAU.
[M100]/W
Port 2 UL path exceeds maximum
gain.
If the problem is common to more than one port, replace
the Hub, otherwise check the RAU.
[M101]/W
Port 2 UL path exceeds maximum
gain.
If the problem is common to more than one port, replace
the Hub, otherwise check the RAU.
[M102]/W
Port 2 UL path exceeds maximum
gain.
If the problem is common to more than one port, replace
the Hub, otherwise check the RAU.
[M103]/W
Port 2 UL path exceeds maximum
gain.
If the problem is common to more than one port, replace
the Hub, otherwise check the RAU.
[M104]/W
Port 8 UL path exceeds maximum
gain.
If the problem is common to more than one port, replace
the Hub, otherwise check the RAU.
[M105]/W
Port 1 54 VDC Power Enabled.
Caution: Port 54 VDC power may be present at the output.
[M106]/W
Port 2 54 VDC Power Enabled.
Caution: Port 54 VDC power may be present at the output.
[M107]/W
Port 3 54 VDC Power Enabled.
Caution: Port 54 VDC power may be present at the output.
[M108]/W
Port 4 54 VDC Power Enabled.
Caution: Port 54 VDC power may be present at the output.
[M109]/W
Port 5 54 VDC Power Enabled.
Caution: Port 54 VDC power may be present at the output.
[M110]/W
Port 6 54 VDC Power Enabled.
Caution: Port 54 VDC power may be present at the output.
[M111]/W
Port 7 54 VDC Power Enabled.
Caution: Port 54 VDC power may be present at the output.
[M112]/W
Port 8 54 VDC Power Enabled.
Caution: Port 54 VDC power may be present at the output.
Table C-5
Warnings/Status Messages for Main Hubs (continued)
Message
Number/
Default
Description
Reason/Action
Содержание InterReach Fusion
Страница 8: ...CONFIDENTIAL 6 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 12: ...CONFIDENTIAL 4 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 16: ...CONFIDENTIAL 4 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 205: ...Help Hot Line U S only 1 800 530 9960 A 3 D 620610 0 20 Rev D CONFIDENTIAL Figure A 2 CommScope 2279V for RG 6...
Страница 214: ...A 12 InterReach Fusion Installation Operation and Reference Manual CONFIDENTIAL D 620610 0 20 Rev D...
Страница 238: ...C 20 InterReach Fusion Installation Operation and Reference Manual CONFIDENTIAL D 620610 0 20 Rev D...