C.4
Faults for RAUs
Table C-4
Faults for RAUs
Message
Number
Description
Reason/Action
{RF01}
Software error occurred and recovered.
If this happens repeatedly, replace the RAU.
{RF02}
Software error occurred and recovered.
If this happens repeatedly, replace the RAU.
{RF03}
Software error occurred and recovered.
If this happens repeatedly, replace the RAU.
{RF04}
Software reset occurred and recovered,
or firmware download.
If this happens repeatedly, replace the RAU.
{RF05}
Software error occurred and recovered.
If this happens repeatedly, replace the RAU.
{RF06}
Problem detected in the RAU.
Contact ADC Support for more information.
{RF07}
RAU power cycle.
RAU power cycle.
{RF08}
Problem detected in the RAU.
Contact ADC Support for more information.
{RF09}
Invalid band.
The RAU doesn't support programmed band. Check the
RAU type against the band programmed in the hub.
{RF10}
Low input DC voltage.
Check the coaxial cable for high RF loss. Try another
Hub port. If the fault persists, replace the RAU. If the
fault clears, mark the Hub port as unusable and replace
the Hub when possible.
{RF11}
Hardware Failure (DL PLL Band 1).
Cycle power once. If the fault persists, replace the RAU.
{RF12}
Hardware Failure (DL PLL Band 2).
Cycle power once. If the fault persists, replace the RAU.
{RF13}
Hardware Failure (DL PLL Band 3).
Cycle power once. If the fault persists, replace the RAU.
{RF14}
Hardware Failure (UL PLL Band 1).
Cycle power once. If the fault persists, replace the RAU.
{RF15}
Hardware Failure (UL PLL Band 2).
Cycle power once. If the fault persists, replace the RAU.
{RF16}
Hardware Failure (UL PLL Band 3).
Cycle power once. If the fault persists, replace the RAU.
{RF17}
Hardware Failure (PA Band 1).
Cycle power once. If the fault persists, replace the RAU.
{RF18}
Hardware Failure (PA Band 2).
Cycle power once. If the fault persists, replace the RAU.
{RF19}
Hardware Failure (PA Band 3).
Cycle power once. If the fault persists, replace the RAU.
{RF20}
Hardware Failure (UL Pilot).
Cycle power once. If the fault persists, replace the RAU.
{RL21}
Commanded Out-of-service (Band 1).
Band 1 commanded out-of-service by User. Command
In-Service on Band 1 to restore service.
{RL22}
Commanded Out-of-service (Band 2).
Band 2 commanded out-of-service by User. Command
In-Service on Band 2 to restore service.
{RL23}
Commanded Out-of-service (Band 3).
Band 3 commanded out-of-service by User. Command
In-Service on Band 3 to restore service.
{RF24}
Problem detected in the RAU.
Contact ADC Support for more information.
{RX25}
Commanded shutdown (Band 1).
Check the status of hub to which the RAU is connected.
{RX26}
Commanded shutdown (Band 2).
Check the status of hub to which the RAU is connected.
{RX27}
Commanded shutdown (Band 3).
Check the status of the hub to which the RAU is con-
nected.
{RF28}
Internal shutdown (Band 1).
RAU Fault condition in band 1 path (or common path).
{RF29}
Internal shutdown (Band 2).
RAU Fault condition in band 2 path (or common path).
{RF30}
Internal shutdown (Band 3).
RAU Fault condition in band 3 path (or common path).
{RF31}
Problem detected in the system.
Contact ADC Support for more information.
{RF32}
Problem detected in the RAU.
Contact ADC Support for more information.
Содержание InterReach Fusion
Страница 8: ...CONFIDENTIAL 6 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 12: ...CONFIDENTIAL 4 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 16: ...CONFIDENTIAL 4 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 205: ...Help Hot Line U S only 1 800 530 9960 A 3 D 620610 0 20 Rev D CONFIDENTIAL Figure A 2 CommScope 2279V for RG 6...
Страница 214: ...A 12 InterReach Fusion Installation Operation and Reference Manual CONFIDENTIAL D 620610 0 20 Rev D...
Страница 238: ...C 20 InterReach Fusion Installation Operation and Reference Manual CONFIDENTIAL D 620610 0 20 Rev D...