C-2
InterReach Fusion Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620610-0-20 Rev D
NOTE:
If you have a red
STATUS
LED without a fault message, it probably
indicates that the unit is locked out.
Table C-1
Fault Messages for Main Hubs
Message
Number
Description
Reason/Action
{MF01}
Software error occurred and recovered.
If this happens repeatedly, replace the Hub.
{MF02}
Software error occurred and recovered.
If this happens repeatedly, replace the Hub.
{MF03}
Software error occurred and recovered.
If this happens repeatedly, replace the Hub.
{MF04}
Software reset occurred and recovered, or
firmware download.
If this happens repeatedly, replace the Hub.
{MF05}
Software error occurred and recovered.
If this happens repeatedly, replace the Hub.
{MF06}
Problem detected in the Hub. Internal
communication reset.
Contact ADC Support for more information.
{MF07}
Hub power cycle.
Hub power cycle.
{MF08}
Internal communications failure.
No internal communications in preceding 15 min-
utes.
{MF09}
Hardware Reset.
Commanded hardware power on reset
{MF10}
Band not programmed.
Use AdminBrowser to program the band.
{MF11}
Hardware failure (DL Pilot PLL).
Cycle power once. If fault persists, replace the Hub
{MF12}
Hardware failure (DL Pilot Too High).
Cycle power once. If fault persists, replace the Hub.
{MF13}
Hardware failure (DL Pilot Too Low).
Cycle power once. If fault persists, replace the Hub.
{MF14}
Hardware failure (54 VDC).
54 VDC power supply is out of range, replace the
Hub
{MF15}
Hardware failure (RF VDC Power).
Loss of DC power to RF circuits, replace the Hub.
{MF16}
Self Lockout (All Bands).
Hub has shutdown the system due to an internal fault.
System is offline.
{MF17}
Hardware failure (DL PLL Band 1).
Cycle power once. If fault persists, replace the Hub.
{MF18}
Hardware failure (UL PLL Band 1).
Cycle power once. If fault persists, replace the Hub
{ML19}
Commanded Out-of-service (Band 1).
Band 1 commanded out-of-service by User.
{MF20}
Hardware failure (UL1 LO2 Band 1).
Cycle power once. If the fault persists, replace the
Hub.
{MF21}
Problem detected in the Hub.
Contact ADC Support for more information.
{MF22}
Problem detected in the Hub.
Contact ADC Support for more information.
{MF23}
Problem detected in the Hub
Contact ADC Support for more information.
{MF24}
Problem detected in the Hub.
Contact ADC Support for more information.
{MF25}
Hardware failure (DL PLL Band 2).
Cycle power once. If fault persists, replace the Hub.
{MF26}
Hardware failure (UL PLL Band 2).
Cycle power once. If fault persists, replace the Hub.
{ML27}
Commanded Out-of-service (Band 2).
Band 2 commanded out-of-service by User.
{MF28}
Problem detected in the Hub.
Contact ADC Support for more information.
{MF29}
Problem detected in the Hub.
Contact ADC Support for more information.
{MF30}
Problem detected in the Hub.
Contact ADC Support for more information.
{MF31}
Problem detected in the Hub.
Contact ADC Support for more information.
{MF32}
Problem detected in the Hub.
Contact ADC Support for more information.
Содержание InterReach Fusion
Страница 8: ...CONFIDENTIAL 6 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 12: ...CONFIDENTIAL 4 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 16: ...CONFIDENTIAL 4 InterReach Fusion Installation Operation and Reference Manual D 620610 0 20 Rev D...
Страница 205: ...Help Hot Line U S only 1 800 530 9960 A 3 D 620610 0 20 Rev D CONFIDENTIAL Figure A 2 CommScope 2279V for RG 6...
Страница 214: ...A 12 InterReach Fusion Installation Operation and Reference Manual CONFIDENTIAL D 620610 0 20 Rev D...
Страница 238: ...C 20 InterReach Fusion Installation Operation and Reference Manual CONFIDENTIAL D 620610 0 20 Rev D...