Estimating RF Coverage
6-20
InterReach Fusion Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620610-0-20 Rev D
Table 6-18
Approximate Radiated Distance from Antenna
for 1900 MHz PCS Applications
Facility
Distance from Antenna
Meters
Feet
Open Environment
72
236
Moderately Open Environment
56
183
Mildly Dense Environment
49
160
Moderately Dense Environment
40
132
Dense Environment
29
96
Table 6-19
Approximate Radiated Distance from Antenna
for 2.1 GHz UMTS Applications
Facility
Distance from Antenna
Meters
Feet
Open Environment
69
226
Moderately Open Environment
54
176
Mildly Dense Environment
47
154
Moderately Dense Environment
39
128
Dense Environment
28
93