The range of acceptable relative humidity is 5% to 95% non-condensing.
8.3.3 Isolation
The PCIe bus and field commons are non-isolated and have a direct
electrical connection.
8.3.4 Vibration and Shock Standards
The AcroPack complies with the following Vibration and Shock standards.
Vibration, Sinusoidal Operating:
Complies with IEC 60068-2-6: 10-
500Hz, 5G, 2 Hours/axis
Vibration, Random Operating:
Complies with IEC 60068-2-64: 10-
500Hz, 5G-rms, 2 Hours/axis
Shock, Operating:
Complies with IEC 60068-2-27: 30G, 11ms half sine, 50G,
3mS half sine, 18 shocks at 6 orientations for both test levels
8.3.5 EMC Directives
The AcroPack complies with EMC Directive 2004/108/EC.
Immunity per EN 61000-6-2:
Electrostatic Discharge Immunity (ESD), per IEC 61000-4-2.
Radiated Field Immunity (RFI), per IEC 61000-4-3.
Electrical Fast Transient Immunity (EFT), per IEC 61000-4-4.
Surge Immunity, per IEC 61000-4-5.
Conducted RF Immunity (CRFI), per IEC 61000-4-6.
Emissions per EN 61000-6-4:
Enclosure Port, per CISPR 16.
Low Voltage AC Mains Port, per CISPR 16.
Note:
This is a Class A product
8.4 Reliability Prediction
MTBF (Mean Time Between Failure):
MTBF in hours using MIL-HDBK-217F,
FN2.
Per MIL-HDBK-217, Ground Benign, Controlled, G
B
G
C
Table 8.4.1 MTBF of APZU-303
Temperature MTBF (Hours)
MTBF (Years)
Failure Rate (FIT
1
)
25°C
1,459,102 167
685.4
40°C
923,762 105.5 1,082.5
1
FIT is Failures in 10
9
hours.