After activating send mode, you receive the following graphic display:
If the receiver beeped twice, the learn message was correctly
received. End the teach process by pressing the control button
under the word
Yes
. To cancel input, press the control button
under the word
No.
The learn procedure now starts again.
No further settings have to be made for the info module. Even in the
case of a power loss, the info module keeps the radio information of
the alarm station.
10.5.2.2. Updates
If you physically remove an Info Module from the system (for
example, a user no longer requires one) then you may wish to stop
the radio alarm panel trying to update the Info Module’s display.
This will free some of the radio alarm panel’s processing power, and
speed up its response to other peripherals. The Info Module menu
provides the
Updates
option for this purpose.
1. Select
Other Devices – Info Module - Updates
.
The display shows the options Disabled and Enabled.
2. Select the option you require.
When you select Enabled, the radio alarm panel carries on
transmitting to the Info Module.
When you select Disabled, the radio alarm panel stops transmitting
data to all the Info Modules.
The default setting for this menu option is Disabled. The radio alarm
panel changes the setting to Enabled when you
teach an Info Module the radio alarm panel’s identity.
10.5.2.3. Ready to set LED
If want the Info Module to display a Ready-to-Set information, which
signalizes an open zone (also zones with the zone attribute force set
omit), you have to activate this function in addition. Please proceed as
follows:
Press the control button
to select
Rdy-to-Set LED
and confirm by
pressing the control button
under the word
Select
. To cancel
input, press the control button
under the word
Back
.
You receive the following graphic display: