PROTECTIVE EARTH CONDUCTOR MULTIPLE CONNECTION
Those connections are connected with each other on the printed circuit board (bus connection).
6.4.10 INTERNAL MAINS SWITCH HUMIDITY
Those terminals are for the internal supply of the optional humidity extension.
6.5.0
HUMIDITY MODULE CONNECTIONS (ASFE)
6.5.1
HUMIDITY SUPPLIES
The neutral conductor “N” and the protective earth conductors
“PE” are multiple connections.
The supply on the right will be connected to the basis module
internally (refer to 6.4.10).
The evaporator will be installed via the cable connection and
will be connected to the terminals L (evaporator), N and PE.
The evaporator needs to have an own safety-turn-off switch
in case of water shortage!
The water shortage connector can be connected to “res. 5”.
The ventilation cable lead in through the cable connection and
connected to the terminals L (ventilation), N and PE. The
outgoing line is secured with a 4 A delay fuse.
6.5.2
HUMIDITY SENSOR AND BENCH SENSOR
Both the bench sensor and the humidity sensor need to be connected to the terminals at the
bottom left. Installation work at the sensors can be made only if the control unit is fully
disconnected from the power line. Connect the circuit just as labelled to the signal cables.
Consider the polarities! Failure can lead to lasting damage.