System Functions and Features as of I7.9
Identification Elements
69
sy
d-
020
0/3.
0
– I7.
9
– 1
1
.2009
3. 7. 4
CLIP format for transit connections in networks
Different CLIP formats are sometimes used in a PISN with PINX in different coun-
tries, with QSIG connection of third-party systems or applications, and with con-
nections via an SIP network.
The CLIP format and an exchange access code can be configured to ensure that the
correct CLIP is displayed in networks whenever possible, even with international
transit connections.
Value range for the parameter
Transit CLIP format
in the trunk group settings
(CM_2_1_3):
•
National
:
– The CLIP for transit connections with incoming national calls is formed in ac-
cordance with
E.164/national
.
– The CLIP for transit connections with incoming international calls is formed in
accordance with
E.164/international
.
•
International
:
The CLIP for transit connections is formed in general in accordance with
E.164/
international
.
•
Unknown with national prefix
:
– The CLIP for transit connections with incoming national calls is formed in ac-
cordance with
E.164/unknown
+
National prefix
+
Transit exchange access pre-
fix
.
– The CLIP for transit connections with incoming international calls is formed in
accordance with
E.164/unknown
+
International prefix
+
Transit exchange ac-
cess prefix
.
•
Unknown with international prefix
:
The CLIP for transit connections is formed in general in accordance with
E.164/
unknown
+
International prefix
+
Transit exchange access prefix
.
The parameter
Transit exchange access prefix
is also located in the trunk group set-
tings and is configurable only if
Transit CLIP format
" is set on
Unknown with national
prefix
or
Unknown with international prefix
.
The parameters
National prefix
and
International prefix
can be found in the basic
settings (CM_1_2_3) under
Own regional prefixes
.