System Functions and Features as of I7.9
Features
485
sy
d-
020
0/3.
0
– I7.
9
– 1
1
.2009
Security elements:
•
Password protection (change the password at regular intervals using AIMS or
the System Assistant on Office 45).
•
External remote control barring throughout the system.
•
Protection for user B for remote control access.
•
Reduction in the choice of remote-controlled features using the special digit
barring facilities of the external remote control
•
Time limit when entering the remote-control sequence:
The */# procedures have to be entered within 12 seconds; thereafter the connec-
tion is cleared down automatically.
•
Access logging:
Remote control attempts from the outside are logged in the incoming call log-
ging (ICL). If the attempt is successful, the DTMF sequence is entered in the field
Dest. No.1
. Unsuccessful attempts are entered with the sort character xx9 (only in
"Structure of the PC5 output format", page 266
System configuration
Tab. 341 External remote control: System configuration
Reference to Other Features
Parameter
Parameter value
Remarks
Password
6 digits exactly with digits (0 to 9)
Adjustable throughout the system at the
attendant authorization (also with the Sys-
tem Assistant on Office 45)
Enable
Yes
Digit barring
Selects the internal digit barring for
switch position 1 to 3 of switch
group 1
Initialization values:
• Digit barring settings:
8/8/8 (2025/2045)
16/16/16 (/2065)
• Digit barring 8/16: *85, *75, #75 barred
Protection against
Remote Control
No
User-specific (enable remote control of the
user’s terminal)
DDI number
<ERC DDI number>
Create DDI number for ERC and link with
CDE
CDE destination
ERC
Can only be entered once a valid password
has been entered
Features:
•
"Remote controlling features from within the system", page 482