background image

Setup guide

A detailed guide for programming and operating a Lutron

®

 

RadioRA

-SR wireless single room lighting control system

English

Français

Espa

ñol

Summary of Contents for RadioRA-SR

Page 1: ...Setup guide A detailed guide for programming and operating a Lutron RadioRA SR wireless single room lighting control system English Français Español ...

Page 2: ...23 9466 If you have any questions the Lutron Technical Support Hotline is ready to help 24 hours a day 7 days a week Call us at 800 523 9466 for immediate assistance For Installation Guides Setup Tools or more information concerning your RadioRA SR system please visit http www lutron com radiorasr ...

Page 3: ...tocol Basics 16 Communication setup 19 Verify assignments and set up Integration IDs 20 Control Command 22 Monitor 25 Error reporting 26 Advanced programming 27 Table of integration operations 29 Resetting devices to factory settings About resetting devices to factory settings 30 Resetting zone controls to factory settings 30 Resetting keypads to factory settings 30 Resetting Pico wireless control...

Page 4: ...ts and scenes at the touch of a button SRD W3B SRD W5BRL SRD W7B Off ADJUST ON PicoTM wireless control Battery powered retrofit portable keypads for zone controls and window treatments SRD P3BRL L SRD P3BRL S System enhancements Integrated Scene Controller Communicates with devices such as universal remote controls and touch screens This allows you to adjust the levels of zone controls and window ...

Page 5: ...Select locations of keypads dimmers and window treatments Drapery tracks for windows Integrated Scene Controller near Audio Visual AV equipment for easy integration All system components must be within this area 3 0 f t 9 m Dimmers for sconces and downlights Tabletop dimmer for reading lamp Keypads at entrance for lights and window treatments System capacities Maximum devices per system 10 includi...

Page 6: ...adioRA SR system A detailed explanation is provided in the Protocol section on page 16 of this guide The manufacturers listed below offer products that are compatible with the RadioRA SR system System planning continued Define scenes and engraving Use the Programming worksheets section on page 32 of this guide to help define your programming Below is a sample worksheet Keypad Type 5 button with ra...

Page 7: ...access scenes 1 2 3 4 and Off 7 button columns can only access scenes 1 2 3 4 5 6 and Off Note Scenes 7 16 can be accessed through the Integrated Scene Controller by using Integration commands See the Protocol section starting on page 16 Programming a keypad column consists of 1 Assigning zone controls keypads and window treatments to a keypad column according to the Assigning devices to a keypad ...

Page 8: ...pad is in assign mode its LEDs will scroll and the LEDs on assigned keypads will continue to flash simultaneously Assigning a keypad column to another keypad column is useful for making the LEDs on all keypad columns track each other All keypads in a room should have the same set of zone controls and window treatments assigned to them 5 Assign the Integrated Scene Controller press the Assign butto...

Page 9: ... second keypad column will only activate the corresponding LED on the second keypad column The first keypad column must also be assigned to the second keypad column in order to allow the LEDs on both keypad columns to be activated when a scene button is pressed on either keypad column 8 Confirm assignment by individually pressing every button on a keypad Assigned devices respond to the button pres...

Page 10: ...OT raise lower from a scene keypad Default levels and positions for a 7 button wall mount keypad Scene Dimmers Switches Window Treatments 1 100 On Open 2 75 On 3 4 open 3 50 On 1 2 open 4 25 On 1 4 open 5 15 On Closed 6 1 On Closed Off 0 Off Closed Default levels and positions for a 3 button wall mount keypad Scene Dimmers Switches Window Treatments 1 100 On Open 3 50 On 1 2 open Off 0 Off Closed ...

Page 11: ...a keypad column is the OFF scene and will turn off all the devices assigned to that column The OFF scene cannot be modified or saved to a different scene 2 Adjust each light and window treatment assigned to that column as follows a Set levels on dimmers use the tapswitch to toggle the lights on or off Use the raise or lower button on the right side of the dimmer to make adjustments to the desired ...

Page 12: ...on turn it off using the tapswitch Pull the FASSTM switch out Press and hold the tapswitch While still holding the tapswitch push the FASS switch in Continue holding the tapswitch until the LED flashes signifying that the next level save will be ignored d Make a window treatment unaffected if the window treatment is open close it using either the clockwise or counter clockwise button Release the b...

Page 13: ... pressing and holding the tapswitch on the dimmer switch until the LED s on the device flash and the load flashes three times approximately 6 seconds Note to unassign a previously assigned dimmer switch repeat steps 1 3 3 Exit assign mode on the sensor by pressing and holding the Lights On and Lights Off buttons on the sensor simultaneously until the LED inside the lens stops flashing approximatel...

Page 14: ...is in assign mode 2 Assign devices to the Integrated Scene Controller column a Assign dimmers switches press and hold the tapswitch on the device until the LED s on the device flash and the load flashes 3 times approximately 6 seconds The LED s on assigned dimmers switches will continue to flash while in assign mode b Assign window treatments press any button on the window treatment drive and the ...

Page 15: ...efore entering scene setup mode The Scene Setup and Assign LEDs should be off If they are not press and hold the Assign button until the LEDs stop flashing approximately 3 seconds 2 Enter scene setup mode on the Integrated Scene Controller by pressing and holding the Assign button on the desired column until the column s Scene Setup LED flashes rapidly approximately 6 seconds Note Pressing and hol...

Page 16: ...es unaffected During normal operation when you press a keypad button a device that is unaffected will ignore the button press The light level or window treatment position will not change To make devices unaffected follow the corresponding step below based on the type of device to be made unaffected a Make a dimmer unaffected if the dimmer is on press the tapswitch once to turn it off After the dim...

Page 17: ...ave been saved approximately 3 seconds 7 Exit scene setup mode on the Integrated Scene Controller by pressing and holding the Assign button of the selected column until the column s Scene Setup LED stops flashing and turns off approximately 6 seconds 8 Confirm scene setup by tapping press and release the Assign button several times until the LED next to the desired scene turns on to confirm which ...

Page 18: ...ry changes to the Integrated Scene Controller using the setup command or Device IP program The Device IP program will allow the installer to detect the Integrated Scene Controller that is either directly connected to a computer or on the same network The installer will be able to see and change the IP address of the Integrated Scene Controller The Device IP program is available on the RadioRA Reso...

Page 19: ...arty equipment such as universal remote controls and software applications to control monitor and query a RadioRA SR system The protocol supports three basic types of integration operations in a RadioRA SR system Command executes an action Query requests the current status Monitor returns responses Note Please see Table of integration operations on page 29 for a list of available integration opera...

Page 20: ... Integrated Scene Controller Monitor output Reports the levels of zone controls and window treatments that are assigned to the Integrated Scene Controller output 12 1 100 device Reports the levels of zone controls and window treatments in the active scene on the Integrated Scene Controller device 12 3 3 error Reports when an incorrect command or query is sent to the Integrated Scene Controller err...

Page 21: ...ers for the Ethernet IP link By default the device leaves the factory with the following network settings IP address 192 168 250 1 IP netmask 255 255 0 0 IP gateway 0 0 0 0 Use the following command to modify these parameters setupisc ethernet ip ip address ip netmask ip gateway Example To set the IP address of the device to 192 168 2 1 netmask to 255 255 255 0 and gateway to 0 0 0 0 use the follo...

Page 22: ... will list the zone controls keypads and window treatments assigned the Integration IDs and the Columns the devices are assigned to For each assigned device it lists a parameter known as the component number In a device with more than one zone each zone will be assigned a unique component number You will only use this number if you modify the integration ID of an output assigned to a zone Example ...

Page 23: ...he serial number and limits the amount of typing errors Please see the Integration ID worksheet below to track the Integration ID and serial number of each zone control and window treatment and which column of the Integrated Scene Controller they are assigned to setupisc set id serial number component number new Integration ID Example To set the Integration ID of a zone control component 3 to 12 w...

Page 24: ...tegration ID is either the user defined number in the table on page 21 or the unique serial number that can be found on a label on the back of each device The serial number of a device assigned to the Integrated Scene Controller can also be found by following the procedure in the List the current devices assigned to the Integrated Scene Controller section on page 20 Use the command string below to...

Page 25: ...ower command sent to the same integration ID Otherwise the zone controls will raise to 100 open or lower to low end closed Note Component numbers 0 Column 1 20 Column 2 40 Column 3 and 60 Column 4 are special numbers that are only used by the Integrated Scene Controller to report that no scene is currently active in the corresponding column Command Action 3 Press 4 Release Scene Component Number C...

Page 26: ...ces assigned to the Integrated Scene Controller can be listed out by using the following command refresh 255 255 Query The current status of devices within a RadioRA SR system can be requested through the Integrated Scene Controller Request device outputs The device outputs for zone controls and window treatments can be requested using the command below output Integration ID 1 Example To request t...

Page 27: ...he back of the device Using the levels of zone controls and window treatments reported by the Integrated Scene Controller For the convenience of the integrator zone control and window treatment levels are reported using the same command format that is provided to control them individually output Integration ID 1 target level Examples When the tapswitch of a dimmer with Integration ID 12 is pressed...

Page 28: ...1 device 12 3 3 When Scene 3 is pressed on a keypad with an Integration ID of 12 which is assigned to column 3 of the Integrated Scene Controller the following is reported to indicate that Scene 3 is active for devices assigned to Column 3 device 12 43 3 When the tapswitch of a dimmer with an Integration ID of 12 is pressed to turn off the dimmer which is assigned to column 1 of the Integrated Sce...

Page 29: ...r 4 Example To enter assign mode for Column 3 on the Integrated Scene Controller setupisc begin prg 3 Note You must now walk around and assign all zone controls and window treatments to this column according to step 2 of the Assigning devices to the Integrated Scene Controller section on page 12 Exit assign mode for Column 3 or 4 This command will allow you to exit the assign mode of column 3 and ...

Page 30: ...pisc scene save button number Example To save the current levels positions of zone controls and window treatments to button number 41 which is on Column 3 of the Integrated Scene Controller setupisc scene save 41 Note The command will only work on zone controls and window treatments that are assigned to the Integrated Scene Controller column that contains the button to be saved List the IP address...

Page 31: ...mmunication baud for the RS232 link setupisc rs232 baud 9600 setupisc ethernet ip ip address ip netmask ip gateway Set the network parameters for the Ethernet IP link setupisc ethernet ip 192 168 2 1 255 255 255 0 0 0 0 0 setupisc list prg List the current devices assigned to the Integrated Scene Controller setupisc list prg setupisc list ip List the IP address Subnet Mask and Gateway settings of ...

Page 32: ...olling the device has been returned to factory settings Reset keypads to factory settings 1 Triple tap and hold any scene button on a keypad DO NOT release the button after the third tap 2 Keep the button pressed on the third tap until all the LEDs start to flash slowly approximately 3 seconds 3 Release the button and immediately triple tap it again The status LEDs will flash quickly When the LEDs...

Page 33: ...sign LEDs continuously flash red 3 Release the Assign button Then press and release it again 4 The Integrated Scene Controller will take several seconds to reset All LEDs will flash red once and the green Scene LEDs will turn on for 3 seconds When the green LEDs turn off reset is complete Reset window treatments to factory settings 1 Press and hold the close limit button on the window treatment dr...

Page 34: ...as needed Keypad Type Location Serial Number Zones 1 2 3 4 5 6 Scene Engraving 1 2 3 4 5 6 7 Raise Lower Always raises lowers lights while being pressed Keypad Type Location Serial Number Zones 1 2 3 4 5 6 Scene Engraving 1 2 3 4 5 6 7 Raise Lower Always raises lowers lights while being pressed 24 7 Technical Support 800 523 9466 ...

Page 35: ...ogrammed incorrectly Program the keypads according to the Programming keypads section starting on page 5 Integrated Scene Controller is not responding to commands Network parameters are not set up correctly Check IP address telnet settings or RS232 connections settings Integrated Scene Controller is not plugged in Plug in Integrated Scene Controller Command strings are incorrect Verify that the co...

Page 36: ...82 103 6 169 377 6 380 696 6 687 487 6 803 728 6 935 403 6 994 145 7 071 634 7 166 970 7 281 565 7 362 285 7 365 282 7 382 100 7 408 525 D439 220 D453 742 D456 783 D461 782 D465 460 D554 071 D554 072 D554 073 and corresponding foreign patents U S and foreign patents pending HomeLogic and ELAN are registered trademarks of ELAN Home Systems LLC Lexington Kentucky NetStreams is a registered trademark...