Operation and Maintenance
242
Aastra 415/430 as of R3.2
syd-0344/1.6 – R3.2 – 09.2014
The system status lines provide useful information for a more in-depth fault diag-
nosis. They can be printed out and sent to customer support on request.
Tab. 112 The displayed data and what it means
System failures menu item
Tab. 113 System failures display
The system's last 80 system failures (restarts) are displayed. The restarts are incre-
mented in the counter in the top right (0...255).
Significance of the display: Error type W = restart (watchdog), date, time
When printing, only the last 4 addresses are printed out.
Power failures menu item
Tab. 114 Power failures display
Only the restart time is recorded.
Display
Description
Normal value/
idle state
Note
BCS
: xxxxx
Number of existing BCS references
BCS
: 00000
Each active connection needs 2
BCS references
CC
: xxxxx
Number of existing call controls
CC
: 00000
For each BCS reference there is
one or more CC
SUBS
: xxxx
Number of users in the system
SUBS
: 0000
0000: No ports busy
NSUB
: xxxx
Number of PISN users in the system
NSUB
: 0000
0000: No PISN user in the system
LINE
: xxxx
Number of lines in the system
LINE
: 0000
0000: No lines defined
DIST
: xxxx
Number of call distributions in the sys-
tem
DIST
: 0000
0000: No call distribution defined
DDIN
: xxxx
Number of DDI numbers in the system
DDIN
: 0000
0000: No DDI numbers defined
ABB
: xxxx
Number of abbreviated dialling num-
bers in the system
ABB:
1000
1000: Default value unchanged
==
SYSTEM FAILURES
52
W 15.09.10
13:32
011A59F2,
011A5A8C,
01156FFE
W 06/12/2010
13:32
011A59F7
011A5A82
01156FF1
==
POWER FAILURES
01/12/2010
16:13