6. 4. 4. 5
Enabling / disabling the dial-up connection to the
AIN
The following sequence changes the status of the remote access to the AIN via an
external dial-up connection:
Requirement:
The system is in
"Application Command Mode", page 208
.
1. Press the pilot key several times with a short keypress (SC) until "F4" lights up.
"F4" indicates the current status: steady red= disabled, steady orange = ena-
bled.
2. Press the pilot key with a long keypress (LC).
After 2 second keypress "F4" lights up green by way of confirmation.
When the key is released, the status changes and the system jumps back to
original Mode.
"F4" indicates the new status: inactive = disabled, steady orange = enabled.
Note:
You are strongly advised to keep the remote access to the AIN via an
external dial-up connection open only for as long as necessary. There is
no time limit to the access and it remains in place even after a system
restart.
6. 4. 4. 6
Carrying out a first start
The following sequence carries out a system first start.
Note:
A first start deletes all the configuration data already stored and replaces
it with the default values of the sales channel. You should therefore
always back up the configuration data prior to a first start by using a data
backup . The system-specific data such as the system ID, system type,
sales channel, licence code, software generation and IP address of the
system are preserved.
Requirement:
The system is in
"Boot Command Mode", page 209
.
1. Press the pilot key briefly.
"F1" lights up red.
2. Press the pilot key with a long keypress (LC).
After 2 second keypress "F1" lights up green by way of confirmation.