Installation
145
Aastra 415/430 as of R3.2
syd-0344/1.6 – R3.2 – 09.2014
Note
Circuit type as per EN/IEC 60950: SELV
Socket
Tab. 73
Connection of Ethernet interfaces
Settings
The IP address can either be taken from a DHCP server in the IP network or config-
ured statically. If a DNS server is used, the communication server can also be ad-
dressed via its host name.
Tab. 74
Default values, IP address
First-start response
The IP addressing after a first start depends on whether a static IP addressing is al-
ready stored on the EIM card from a previous configuration. A static IP addressing
(IP address, subnet mask, gateway) entered manually is stored on the EIM card and
remains available after a first start. This means that the communication server re-
mains accessible via Ethernet interface in the same way as before the first start.
If no IP addressing is entered on the EIM card (e.g. after initial delivery), the commu-
nication server is started with DHCP after a first start. The communication server
tries to log on with the DHCP server and to enter its host name on the DNS server. If
logon is successful the communication server is accessible via the host name.
RJ45 socket
Pin
Signal
1
Tx+
2
Tx–
3
Rx+
4
—
5
—
6
Rx–
7
—
8
—
Parameter
Parameter value
IP address
192.168.104.13
Subnet mask
255.255.255.0
Gateway
0.0.0.0
DHCP
yes
Host name
<Model name>-<MAC-Address>
1)
Example: Aastra430-00085d803100
1)
This entry is hidden and does not appear in the parameter’s input field