Installation
89
Aastra 415/430 as of R3.2
syd-0344/1.6 – R3.2 – 09.2014
Warning
Be sure to observe the
"Safety regulations", page 82
.
4. Remove the housing cover.
5. Aastra 430 only:
Install the fan (see
"Installing the fan", page 89
).
6. Connect the earthing (see
"Connecting the earthing wire", page 92
).
7. Fit the housing cover.
8. Secure the cage nuts in the appropriate positions in the rack’s fastening rails (see
Fig. 16
).
9. Secure the communication server to the rack’s fastening rails using the M6
screws, the plastic washers and the cage nuts.
10.Fasten the snap-on tag to the front panel.
11.Reconnect the communication server to the power supply.
4. 2. 7. 2
Installing the fan
Materials required:
• Fan from the Aastra 430 rack-mounting kit
• 2 screws from the Aastra 430 rack-mounting set
• Screwdriver
To install the fan proceed as follows:
1. Shut down the communication server (see
"Shutdown Mode", page 211
) and
disconnect it from the power supply.
Warning
Be sure to observe the
"Safety regulations", page 82
.
2. Remove the housing cover.
3. Use the two screws to fit the fan to the inside of the housing. Take note of the ar-
rows on the fan. They indicate the direction of rotation and the air flow. The air
must flow out of the housing of the communication server (see
Fig. 17
).
4. Plug the fan connector into the socket marked "FAN" on the mainboard.
5. Fit the housing cover.
6. Reconnect the communication server to the power supply.