122 | Managing the Radio
Aprisa SR+ User Manual 1.11.1
RF Operating Mode
The RF Operating Mode defines the operation of the RF over-the-air. The default setting is Standard.
Option
Function
Standard
The radio operates normally.
Disabled
Disables all RF over-the-air communications from the RF port and
turns off the transmitter and receiver to save power.
This enables a radio to be used as a Terminal Server without RF.
TERMINAL PROTECTION
Protection Type
The Protection Type defines if a radio is a stand-alone radio or part of an Aprisa SR+ Protected Station. The
default setting is None.
Option
Function
None
The SR+ radio is stand-alone radio (not part of an Aprisa SR+
Protected Station).
Redundant
(Protected Station)
Set to make this SR+ radio part of an Aprisa SR+ Protected Station.
The RF ports and interface ports from two standard Aprisa SR+
radios are switched to the standby radio if there is a failure in the
active radio.
Monitored Hot Standby
(Protected Station)
Set to make this SR+ radio part of an Aprisa SR+ Protected Station.
The RF ports and interface ports from two standard Aprisa SR+
radios are switched to the standby radio if there is a failure in the
active radio.
The standby radio is monitored to ensure its correct operation
should a switch-over be required. See
’ on page
409 for the list of monitored alarms.
Serial Data Driven Switching Set to make this SR+ radio part of an Aprisa SR+ Data Driven
Protected Station.
Protection Unit
The Protection Unit defines if this radio is the primary radio or secondary radio in a Protected Station.
One radio in the Protected Station is set to Primary and the other radio to Secondary.
It is recommended that radio A (the left radio) be configured as the Primary and that radio B (the right
radio) be configured as the Secondary. The default setting is Primary.
This menu item is only applicable if this radio is to become part of an Aprisa SR+ Protected Station.
PROTECTION MANAGEMENT IP ADDRESS
Local IP Address
The Local IP Address shows the IP address of this radio.
Partner IP Address
The Partner IP Address parameter is used to set the partner IP address if this radio is to become part of a
Protected Station.
Содержание Aprisa SR+
Страница 1: ...January 2021 Version 1 11 1b ...
Страница 2: ......
Страница 10: ......
Страница 72: ......
Страница 86: ......
Страница 317: ...Managing the Radio 317 Aprisa SR User Manual 1 11 1 The Graph Current button presents a graph of current results ...