166 | Managing the Radio
Aprisa SR+ User Manual 1.11.1
Inter-Frame Gap (chars)
This parameter defines the gap between successive serial data frames. It is used to delimit the serial data
to define the end of a packet.
Smaller values give better serial latency, however if this value is too small then packets may be incorrectly
split and serial speed may be much slower. If this value is too large serial packets may be incorrectly joined
together.
The Inter-Frame Gap limits are 0 to 9999 chars in steps of 0.1 char. The default setting is 3.5 chars.
An alarm event indicates if the value is set larger than the maximum for the serial mode selected.
Содержание Aprisa SR+
Страница 1: ...January 2021 Version 1 11 1b ...
Страница 2: ......
Страница 10: ......
Страница 72: ......
Страница 86: ......
Страница 317: ...Managing the Radio 317 Aprisa SR User Manual 1 11 1 The Graph Current button presents a graph of current results ...