Managing the Radio | 305
Aprisa SR+ User Manual 1.11.1
The remote radios will be polled to determine which radios require activation:
Result
Function (X of Y)
Remote Radios Polled for
Partners
X is the number of radios polled to determine the number of
protected stations in the network.
Y is the number of remote radios registered with the base station.
Remote Radios Polled for
New Version
X is the number of radios polled to determine the number of radios
that contain the new software version.
Y is the number of remote radios registered with the base station.
Remote Radios Activated X is the number of radios that contain the new software version
and have been activated.
Y is the number of radios that contain the new software version
and can be activated.
Remote Radios On New
Version
X is the number of radios that has been successfully activated and
now running the new version of software.
Y is the number of radios that the activation command was
executed on.
Note:
When upgrading from software version 1.2.5 to 1.2.6 or
later, communication to all remote radios will be lost due to a MAC
protocol change. This will prevent this function from working
correctly. In this case, activate the new software on the base
station and run the
Discover Nodes
function on page 276.
When the activation is ready to start:
4.
Click on ‘OK’ to start the activation process or Cancel to
quit.
Содержание Aprisa SR+
Страница 1: ...January 2021 Version 1 11 1b ...
Страница 2: ......
Страница 10: ......
Страница 72: ......
Страница 86: ......
Страница 317: ...Managing the Radio 317 Aprisa SR User Manual 1 11 1 The Graph Current button presents a graph of current results ...