In AutoCAD, when you load the drawing file, you might see messages
about the files not being found. To check for external references, you can
select
Insert > Xref Manager
. If you look at the layers, externally
referenced layers have a common prefix label with the $ delimiter
between the label and the description (for example, SC03$a-WALL-FULL).
If you can see the layer itself, the layer either will be blank or will be a
single read-only object.
To include the information in externally referenced files, place the files in
the same directory as the master file. In AutoCAD, you also can bind the
information to the master file by selecting
Insert > Xref Manager
,
selecting the file, then clicking Bind.
Adding information from referenced files can increase the file size. If the
information you will need to convert into RF obstacles is in the referenced
file, but not the master file, try just importing the referenced file into
3WXM. For information on the location of referenced files in AutoCAD,
see the AutoCAD documentation.
Audit the drawing. An audit finds problems between objects in the file
and fixes them automatically. To perform an audit in AutoCAD, select
File > Drawing Utilities > Audit
.
Check for grouped objects, especially groups that span multiple layers
or include the entire drawing. If a grouped object contains objects that
you will to assign differing RF values to, or if some objects will not
become RF obstacles, ungroup the objects and delete the unneeded
objects. If all the RF objects in the grouped object will have the same
RF value, you might want to leave the object grouped.
A grouped object can contain multiple layers, and can contain visible
and invisible objects. (When you select an object that spans multiple
layers, the object is not selected normally when you click on it.
Instead, a selection square appears, offset to the side of the object.) If
you decide to delete a grouped object, ensure that the object does not
contain objects to which you will need to assign RF values.
Turn visible, unlock, and unfreeze all layers. Then delete unnecessary
layers. (Locking a layer keeps the layer visible but also prevents changes
to the layer. Freezing a layer locks the layer and makes it invisible.)
In many cases, the information in invisible or frozen layers is not
related to objects that will be RF obstacles, and so is unnecessary in
the floor plan. The information you need to keep is the structural
information to which you will assign RF values in 3WXM.
Содержание OfficeConnect WX1200
Страница 16: ......
Страница 48: ...48 CHAPTER 2 WORKING WITH THE 3WXM USER INTERFACE ...
Страница 236: ...236 CHAPTER 6 CONFIGURING WX SYSTEM PARAMETERS ...
Страница 288: ...288 CHAPTER 7 CONFIGURING WIRELESS PARAMETERS ...
Страница 332: ...332 CHAPTER 8 CONFIGURING AUTHENTICATION AUTHORIZATION AND ACCOUNTING PARAMETERS ...
Страница 364: ...364 CHAPTER 10 MANAGING WX SYSTEM IMAGES AND CONFIGURATIONS ...
Страница 476: ...476 CHAPTER 17 DETECTING AND COMBATTING ROGUE DEVICES ...
Страница 492: ...492 CHAPTER A CHANGING 3WXM PREFERENCES ...
Страница 514: ...514 APPENDIX C OBTAINING SUPPORT FOR YOUR 3COM PRODUCTS ...
Страница 520: ...520 INDEX ...