66
C
HAPTER
3: G
ENERAL
T
ASKS
Enter parameter(s): 0-Enhanced redund. 1-Basic redund.
Enter
0
to specify enhanced redundancy.
The following message appears:
Full redundancy mode invoked.
If you are unable to configure enhanced mode because of incorrect
modules in the chassis, this message appears:
No proper IFC is populated.
For more information on allowed module types for enhanced
redundancy, see Chapter 10 in the Operations Guide.
Set Redundant
Switch Mode
Sets the redundant switch mode.
Command Actions
Command Result
Example
Enter:
1 1 13 3
The following prompt is displayed:
Enter parameter(s): 0-Standby 1-Suspended
Enter
0
to specify standby mode for the redundant switch.
Enter the menu sequence:
(1) SYS: Platform config
(1) SET: Switch setup
(13) SRS: Switch Redundancy setup
(3) SSM: Set redundant switch mode
Enter a parameter at the prompt
Parameter
Format
Redundant switch mode
0 - Standby
1 - Suspended
Direct access sequence:
1 1 13 3
[parameter]
System action taken:
The redundant switch mode is set.
System message display:
Standby mode is invoked.