Setting Up for Management
81
Update Write
Community String
Address
Updates the Write Community String of the CoreBuilder 7000 family
ATM switch. The Write Community String is updated after the next
reboot of the switch.
Command Actions
Command Result
Example
Enter:
1 1 2 6 2 private
The Write Community String is updated to private.
Enter the menu sequence:
(1) SYS: Platform config
(1) SET: Switch setup
(2) MNG: Management setup
(6) SET: Set Comm. String Setup
(2) SET: Set & save Set Comm.
String
Enter a parameter at the prompt
Parameter
Format or Range
Write Community String alphanumeric string up to 19 characters (normally set
to “public” or “private”)
Direct access sequence:
1 1 2 6 2
[parameters]
System action taken:
The Write Community String is updated after the next
reboot of the switch.
System message display:
Set community string was set for next reboot.