Setting Up for Management
77
Update Subnet Mask
Address
Updates the subnet mask address of the CoreBuilder 7000 family ATM
switch. The default factory subnet mask address is 255.255.255.0. The
subnet mask address is updated after the next reboot of the switch.
Run the integrated fast setup to configure this parameter.
Command Actions
Command Result
Example
Enter:
1 1 2 4 2 255.255.255.0
The Subnet Mask address is updated to 255.255.255.0.
Enter the menu sequence:
(1) SYS: Platform config
(1) SET: Switch setup
(2) MNG: Management setup
(4) MSK: Subnet Mask Setup
(2) SSM: Set & Save Subnet Mask
Enter a parameter at the prompt
Parameter
Format or Range
Subnet mask address
valid IP address
Direct access sequence:
1 1 2 4 2
[parameters]
System action taken:
The subnet mask address is updated after the next
reboot of the switch.
System message display:
Run integrated fast setup to configure
this parameter.