Ignore Interface Card Slot
115
Ignore Interface
Card Slot
Updates the interface card ignore-slot parameter. The ignore-slot
parameter can take the values Ignore and Normal. For more information
“Display Interface Card Ignore-Slot Status” on page 114.
Use this command to disconnect an interface card from the switch
without having to physically remove it.
Use this command also to reset a module installed in a specified slot
without physically removing it: perform the command twice, first with
‘Ignore’ and then with ’Normal’.
Command Actions
Command Result
Example
Enter:
1 3 5 3 0
The following message is displayed:
Status has been changed.
The ignore-slot parameter of slot 3 is set to Ignore.
Enter the menu sequence:
(1) SYS: Platform config
(3) LOA: Load system software
(5) SSI: Set 'ignore slot' status
Enter a parameter at the prompt
Parameter
Format or Range
Slot ID
3–6
Ignore slot status
0
for Ignore
1
for Normal
Direct access sequence:
1 3 5
[parameters]
System action taken:
The ignore slot parameter is set to the specified value.
System message display:
Status has been changed.
Содержание CoreBuilder 7000
Страница 16: ......
Страница 68: ...68 CHAPTER 3 GENERAL TASKS ...
Страница 164: ...164 CHAPTER 6 ILMI CONFIGURATION ...
Страница 462: ...462 CHAPTER 13 CONFIGURING AND MANAGING PNNI FOR THE EXTENDED VERSION ONLY ...
Страница 468: ...468 APPENDIX A TECHNICAL SUPPORT ...
Страница 472: ...472 APPENDIX B COREBUILDER 7000 FAMILY ATM SWITCH SPECIFICATIONS ...
Страница 476: ...476 APPENDIX C SAFETY INFORMATION ...
Страница 514: ...514 INDEX ...