Setting the Timers
397
Set PTSE Holddown
Timer
Sets the PTSE holddown timer value. The PTSE holddown timer value is
the value (expressed in milliseconds) used by the specified node to limit
the rate at which it can send PTSEs. A change to the PTSE holddown
timer value takes place after the next reboot. For more information on
PTSEs, see “PTSE” on page 78 in the Operations Guide.
Command Actions
Command Result
Example
Enter:
1 1 10 4 3 4 1 5
The following message is displayed:
Default Value is 10 (1 sec), new value is 5
Press ENTER to continue...
Enter menu sequence:
(1) SYS: Platform config
(1) SET: Switch setup
(10) PNI: PNNI Setup
(4) CFP: Configure PNNI
(3) NCF: Node Configuration
(4) TIM: Timers
(1) PHD: PTSE Holddown Timer
Enter a parameter at the prompt
Parameter
Format or Range
interval
1 - 30000 milliseconds
Direct access sequence:
1 1 10 4 3 4 1
[parameters]
System action taken:
The PTSE holddown timer values is displayed and is
updated to its new value.
System message display:
Default value is <x>, new value is <y>